share:

Restek Searchable Chromatogram Library

You've Selected:

Market Area:
Air
Clear All Selections

Enter a compound, synonym, CAS #, compound class, column name, or keyword below.

Examples:
1,4-dioxane
123-91-1, pyrene and chrysene
semivolatiles and rxi5silms
8270

You are currently filtering on:

Dioxane[x]

Enter more terms to filter the results further.

TO-15 (HJ759) + PAMS on Rt-Alumina BOND/MAPD (by FID) and Rxi-624Sil MS (by MS) using Deans Switch

GC_AR1172

Column: Rxi-624Sil MS, 60 m, 0.25 mm ID, 1.40 µm (cat.# 13869), with zero dead volume Valco internal union (cat.# 20150)
Injector: On-Column
Detector: MS-Scan

NJ Low Level TO-15 75 Component Mix on Rtx-VMS (60 m, 40 °C start)

GC_AR1167

Column: Rtx-VMS, 60 m, 0.25 mm ID, 1.40 µm (cat.# 19916), with MXT low-dead-volume connector kit (cat.# 20536)
Injector: On-Column
Detector: MS-Scan

NJ Low Level TO-15 75 Component Mix on Rtx-VMS (30 m, 2.0 mL/min)

GC_AR1165

Column: Rtx-VMS, 30 m, 0.25 mm ID, 1.40 µm (cat.# 19915), with MXT low-dead-volume connector kit (cat.# 20536)
Injector: On-Column
Detector: MS-Scan

TO-15 65 Component Mix on Rxi-1ms (60 m)

GC_AR1156

Column: Rxi-1ms, 60 m, 0.32 mm ID, 1.00 µm (cat.# 13357)
Injector: Direct
Detector: MS-Scan

TO-15 65 Component Mix on Rxi-5Sil MS (30 m)

GC_AR1157

Column: Rxi-5Sil MS, 30 m, 0.32 mm ID, 1.00 µm (cat.# 13654)
Injector: Direct
Detector: MS-Scan

TO-15 65 Component Mix on Rtx-VMS (30 m, 1.2 mL/min)

GC_AR1155

Column: Rtx-VMS, 30 m, 0.25 mm ID, 1.40 µm (cat.# 19915)
Injector: Direct
Detector: MS-Scan

TO-15 65 Component Mix on Rtx-VMS (30 m, 2.0 mL/min)

GC_AR1154

Column: Rtx-VMS, 30 m, 0.25 mm ID, 1.40 µm (cat.# 19915)
Injector: Direct
Detector: MS-Scan

TO-15 65 Component Mix on Rtx-VMS (30 m)

GC_AR1153

Column: Rtx-VMS, 30 m, 0.32 mm ID, 1.80 µm (cat.# 19919)
Injector: Direct
Detector: MS-Scan

Volatile Organics TO-15 Volatiles on Rtx-1

GC_EV00731

Column: Rtx-1, 60 m, 0.32 mm ID, 1.00 µm (cat.# 10157)
Injector: Direct
Detector: MS-Scan

TO-15 65 Component Mix on Rxi-5Sil MS (30 m, 1.5 mL/min)

GC_AR1152

Column: Rxi-5Sil MS, 30 m, 0.32 mm ID, 1.00 µm (cat.# 13654)
Injector: Direct
Detector: MS-Scan

TO-15 65 Component Mix on Rxi-5Sil MS (30 m, 2.0 mL/min)

GC_AR1150

Column: Rxi-5Sil MS, 30 m, 0.32 mm ID, 1.00 µm (cat.# 13654)
Injector: Direct
Detector: MS-Scan

TO-15 65 Component Mix on Rxi-5ms (30 m)

GC_AR1149

Column: Rxi-5ms, 30 m, 0.32 mm ID, 1.00 µm (cat.# 13454)
Injector: Direct
Detector: MS-Scan

TO-15 65 Component Mix on Rxi-624Sil MS (30 m)

GC_AR1148

Column: Rxi-624Sil MS, 30 m, 0.32 mm ID, 1.80 µm (cat.# 13870)
Injector: Direct
Detector: MS-Scan

TO-15 65 Component Mix on Rxi-1ms (30 m)

GC_AR1147

Column: Rxi-1ms, 30 m, 0.32 mm ID, 1.00 µm (cat.# 13354)
Injector: Direct
Detector: MS-Scan

Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us