3-Monochloropropane-1,2-Diol (3-MCPD) Esters in Olive Oil on Rxi-17Sil MS

GC_FS0566

Column: Rxi-17Sil MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 14123)
Injector: Split
Detector: MS-SIM

EPA and EU Phthalates on Rtx-CLPesticides2

GC_EV1416

Column: Rtx-CLPesticides2, 30 m, 0.25 mm ID, 0.20 µm (cat.# 11323)
Injector: Split
Detector: MS-Scan

EPA and EU Phthalates on Rtx-50

GC_EV1415

Column: Rtx-50, 30 m, 0.25 mm ID, 0.25 µm (cat.# 10523)
Injector: Split
Detector: MS-Scan

EPA and EU Phthalates on Rtx-CLPesticides

GC_EV1414

Column: Rtx-CLPesticides, 30 m, 0.25 mm ID, 0.25 µm (cat.# 11123)
Injector: Split
Detector: MS-Scan

EPA and EU Phthalates on Rxi-5ms

GC_EV1412

Column: Rxi-5ms, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13423)
Injector: Split
Detector: MS-Scan

EPA and EU Phthalates on Rxi-XLB

GC_EV1409

Column: Rxi-XLB, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13723)
Injector: Split
Detector: MS-Scan

EPA and EU Phthalates on Rtx-440

GC_EV1408

Column: Rtx-440, 30 m, 0.25 mm ID, 0.25 µm (cat.# 12923)
Injector: Split
Detector: MS-Scan

EPA and EU Phthalates on Rxi-35Sil MS

GC_EV1413

Column: Rxi-35Sil MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13823)
Injector: Split
Detector: MS-Scan

EPA Method 8061A Phthalates on Rtx-440

GC_EV1406

Column: Rtx-440, 30 m, 0.25 mm ID, 0.25 µm (cat.# 12923)
Injector: Split
Detector: MS-Scan

Chlorophenoxyacid Herbicides (methyl esters) US EPA Method 515 by GC/ECD on Rtx-440

GC_EV00756

Column: Rtx-440, 30 m, 0.32 mm ID, 0.25 µm (cat.# 12924)
Injector: Splitless
Detector: ECD

Chlorophenoxyacid Herbicides (methyl esters) US EPA Method 515 by GC/ECD on Rtx-CLPesticides2

GC_EV00755

Column: Rtx-CLPesticides2, 30 m, 0.32 mm ID, 0.25 µm (cat.# 11324)
Injector: Splitless
Detector: ECD

EPA Method 8060 Phthalate Esters on Rtx-5 (Direct Injection)

GC_EV00036

Column: Rtx-5, 30 m, 0.53 mm ID, 0.50 µm (cat.# 10240)
Injector: Direct
Detector: FID

Alcholic Beverages Acids and Esters on Stabilwax-DA

GC_FF00526

Column: Stabilwax-DA, 30 m, 0.18 mm ID, 0.18 µm (cat.# 550752)
Injector: Splitless
Detector: FID

Esters on Stabilwax

GC_CH00314

Column: Stabilwax, 60 m, 0.53 mm ID, 1.00 µm (cat.# 10658)
Injector: Split
Detector: MS-Scan

Phthalate Esters by U.S. EPA Method 606 on MXT-5

GC_EV00035

Column: MXT-5, 30 m, 0.53 mm ID, 1.00 µm (cat.# 70255)
Injector: Split
Detector: FID

Phthalate Esters by U.S. EPA Method 606 on Rtx-5

GC_EV00034

Column: Rtx-5, 30 m, 0.53 mm ID, 1.50 µm (cat.# 10270)
Injector: Splitless
Detector: FID

Alcoholic Beverages (Acids and Esters): Caproic Acid and Ethyl Laurate on Stabilwax-DA

GC_FF00525

Column: Stabilwax-DA, 30 m, 0.18 mm ID, 0.18 µm (cat.# 550752)
Injector: Splitless
Detector: FID

Underivatized Alcoholic Beverage Acids and Methyl Esters on Stabilwax-DA

GC_FF00500

Column: Stabilwax-DA, 30 m, 0.18 mm ID, 0.18 µm
Injector: Splitless
Detector: FID

Endocrine Disruptors: Phthalate Esters on Rtx-5MS

GC_EV00049

Column: Rtx-5MS, 30 m, 0.25 mm ID, 0.50 µm (cat.# 12638)
Injector: Cold On-column
Detector: MS-SIM

Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us