share:

Restek Searchable Chromatogram Library

Enter a compound, synonym, CAS #, compound class, column name, or keyword below.

Examples:
1,4-dioxane
123-91-1, pyrene and chrysene
semivolatiles and rxi5silms
8270

You are currently filtering on:

fast[x]

Enter more terms to filter the results further.

Fast Analysis of 3-MCPD and 2-MCPD on Rxi-17Sil MS

GC_FS0569

Column: Rxi-17Sil MS, 20 m, 0.18 mm ID, 0.18 µm (cat.# 14102)
Injector: PTV Split
Detector: MS-SIM

Fast Dual Column Analysis of Organochlorine Pesticides (EPA Method 8081) Using a GC Accelerator Kit and Rtx-CLPesticides and Rtx-CLPesticides2 Column Set

GC_EV1498

Column: Rtx-CLPesticides 30 m, 0.32 mm ID, 0.32 µm (cat.# 11141-051), and Rtx-CLPesticides2 30 m, 0.32 mm ID, 0.25 µm (cat.# 11324-051), using Rxi guard column 5 m, 0.32 mm ID (cat.# 10039), with universal angled “Y” Press-Tight connector (cat.# 20403-261)
Injector: Splitless
Detector: Micro-ECD

Fast Dual Column Analysis of Organochlorine Pesticides (EPA Method 8081) Using a GC Accelerator Kit and Rtx-CLPesticides and Rtx-CLPesticides2 Column Set

GC_EV1496

Column: Rtx-CLPesticides 30 m, 0.25 mm ID, 0.25 µm (cat.# 11123-051), and Rtx-CLPesticides2 30 m, 0.25 mm ID, 0.20 µm (cat.# 11323-051), using Rxi guard column 5 m, 0.25 mm ID (cat.# 10029), with universal angled “Y” Press-Tight connector (cat.# 20403-261)
Injector: Splitless
Detector: Micro-ECD

16 Priority PAHs and Methylnaphthalenes on Rxi- 5Sil MS using the GC Accelerator Kit in a 208 V Oven

GC_EV1448

Column: Rxi-5Sil MS, 20 m, 0.15 mm ID, 0.15 µm (cat.# 43816)
Injector: Split
Detector: MS-SIM

16 Priority PAHs and Methylnaphthalenes on Rxi-5Sil MS using the GC Accelerator Kit in a 120 V Oven

GC_EV1472

Column: Rxi-5Sil MS, 20 m, 0.15 mm ID, 0.15 µm (cat.# 43816)
Injector: Split
Detector: MS-SIM

EPA Method 541 UCMR4 Standard at Method Reporting Limit on Stabilwax (SIM)

GC_EV1468

Column: Stabilwax, 30 m, 0.25 mm ID, 0.50 µm (cat.# 10638)
Injector: Pulsed Splitless
Detector: MS-SIM

EPA Method 541 UCMR4 Standard at 10x the Method Reporting Limit on Stabilwax (SIM)

GC_EV1469

Column: Stabilwax, 30 m, 0.25 mm ID, 0.50 µm (cat.# 10638)
Injector: Pulsed Splitless
Detector: MS-SIM

Reformate Standard on Rtx-DHA 50 by Optimized ASTM D5134-13

GC_PC1320

Column: Rtx-DHA-50, 50 m, 0.20 mm ID, 0.50 µm (cat.# 10147)
Injector: Split
Detector: FID

Electronic Cigarette Liquid on Rtx-VMS (Hydrogen/Fast Ramp)

GC_FF1257

Column: Rtx-VMS, 30 m, 0.25 mm ID, 1.40 µm (cat.# 19915)
Injector: Split
Detector: FID

Patchouli Oil Fast GC/MS on Rtx-5

GC_FF00851

Column: Rtx-5, 10 m, 0.10 mm ID, 0.10 µm (cat.# 41201)
Injector: Split
Detector: MS-Scan

Organochlorine Pesticides Fast Analysis Conditions on Rtx-CLPesticides & Rtx-CLPesticides2 (dual column analysis)

GC_EV00740

Column: Rtx-CLPesticides 30 m, 0.32 mm ID, 0.50 µm (cat.# 11139), and Rtx-CLPesticides2 30 m, 0.32 mm ID, 0.25 µm (cat.# 11324), using Siltek Guard Column .15 m, 0.32 mm ID (cat.# 10027), with Universal Angled “Y” Press-Tight Connector (cat.# 20403)
Injector: Splitless
Detector: ECD

Carboxylic Acids on Ultra Aqueous C18 (Fast Analysis)

LC_0306

Column: Ultra Aqueous C18 Fast LC Cartridge (cat.# 91783340), Dimensions:30 mm x 4.0 mm ID, Particle Size: 3 µm, Pore Size: 100 Å, Temperature: Ambient
Detector: UV/Vis

Pesticides (Carbamates) on Ultra Carbamate (Fast LC)

LC_0225

Column: Ultra Carbamate (cat.# 9177355), Dimensions:50 mm x 4.6 mm ID, Particle Size: 3 µm, Pore Size: 100 Å, Temperature: 27 °C
Detector: UV/Vis

Vanillin and Ethyl Vanillin on Pinnacle DB C18 (Fast LC)

LC_0251

Column: Pinnacle DB C18 (cat.# 9414555), Dimensions:50 mm x 4.6 mm ID, Particle Size: 5 µm, Pore Size: 140 Å, Temperature: 27 °C
Detector: UV/Vis

Aromatic Amino Acids on Ultra Aqueous C18 (Fast Analysis)

LC_0307

Column: Ultra Aqueous C18 (cat.# 9178535), Dimensions:30 mm x 4.6 mm ID, Particle Size: 5 µm, Pore Size: 100 Å, Temperature: 50 °C
Detector: UV/Vis

Bergamot Oil Fast GC/MS on Rtx-5

GC_FF00850

Column: Rtx-5, 10 m, 0.10 mm ID, 0.10 µm (cat.# 41201)
Injector: Split
Detector: MS-Scan

Hydrocarbons, C44-C100 MXT-1HT Sim Dist (fast GC)

GC_PC00531

Column: MXT-1HT SimDist, 5 m, 0.53 mm ID, 0.10 µm (cat.# 70100)
Injector: On-Column
Detector: FID

Organic Volatile Impurities Rtx-200 & Rtx-WAX (GC xGC)

GC_PH00888

Column: Rtx-200 60 m, 0.25 mm ID, 1.00 µm (cat.# 15056)Rtx-Wax 2 m, 0.18 mm ID, 0.3 µm (cat.# custom)
Injector: Split
Detector: FID

Fast Detailed Hydrocarbons Analysis (DHA) on Rtx-DHA-100/Rtx-5 DHA

GC_PC00774

Column: Rtx-DHA-100, 100 m, 0.25 mm ID, 0.50 µm (cat.# 10148), using Rtx-5 DHA tuning column* 2-5 m, 0.25 mm ID,
Injector: Split
Detector: FID

Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us