Restek Searchable Chromatogram Library
Show Filters
Enter a compound, synonym, CAS #, compound class, column name, or keyword below.
Examples:
1,4-dioxane
123-91-1, pyrene and chrysene
semivolatiles and rxi5silms
8270
Comparison of Glycols Before and After 600 Water Injections on Rtx-Wax
GC_EV1454

Column: Rtx-Wax, 30 m, 0.53 mm ID, 1.00 µm (cat.# 12455)
Injector: Split
Detector: FID
Injector: Split
Detector: FID
Glycol Ethers of Regulatory Importance on Rxi-1301Sil MS
GC_PC1280

Column: Rxi-1301Sil MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 16094)
Injector: Split
Detector: MS-Scan
Injector: Split
Detector: MS-Scan
Comprehensive Glycol Ether Mix on Rxi-1301Sil MS
GC_PC1279

Column: Rxi-1301Sil MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 16094)
Injector: Split
Detector: MS-Scan
Injector: Split
Detector: MS-Scan
Glycol Ethers of Regulatory Importance on Rtx-624
GC_PC1282

Column: Rtx-624, 30 m, 0.25 mm ID, 1.40 µm (cat.# 10968)
Injector: Split
Detector: MS-Scan
Injector: Split
Detector: MS-Scan
Custom Cleaning Solvents Standard on Stabilwax-MS
GC_GN1164

Column: Stabilwax-MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 10673)
Injector: Split
Detector: MS-Scan
Injector: Split
Detector: MS-Scan
Custom Solvents Mix on Stabilwax-MS
GC_GN1163

Column: Stabilwax-MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 10673)
Injector: Split
Detector: MS-Scan
Injector: Split
Detector: MS-Scan
Solvent Mixture #1 on Rtx-1
GC_CH00335

Column: Rtx-1, 60 m, 0.53 mm ID, 3.00 µm (cat.# 10188)
Injector: Split
Detector: MS-Scan
Injector: Split
Detector: MS-Scan
Solvent Mixture #1 on Rtx-200
GC_CH00336

Column: Rtx-200, 60 m, 0.53 mm ID, 3.00 µm (cat.# 15088)
Injector: Split
Detector: MS-Scan
Injector: Split
Detector: MS-Scan
Solvent Mixture #1 on Stabilwax
GC_CH00337

Column: Stabilwax, 60 m, 0.53 mm ID, 1.00 µm (cat.# 10658)
Injector: Split
Detector: MS-Scan
Injector: Split
Detector: MS-Scan
Solvent Mixture #2 on Rtx-1
GC_CH00338

Column: Rtx-1, 60 m, 0.53 mm ID, 3.00 µm (cat.# 10188)
Injector: Split
Detector: MS-Scan
Injector: Split
Detector: MS-Scan
Solvent Mixture #2 on Rtx-200
GC_CH00339

Column: Rtx-200, 60 m, 0.53 mm ID, 3.00 µm (cat.# 15088)
Injector: Split
Detector: MS-Scan
Injector: Split
Detector: MS-Scan
Solvent Mixture #2 on Stabilwax
GC_CH00340

Column: Stabilwax, 60 m, 0.53 mm ID, 1.00 µm (cat.# 10658)
Injector: Split
Detector: MS-Scan
Injector: Split
Detector: MS-Scan
Solvent Mixture #3 on Rtx-1
GC_CH00341

Column: Rtx-1, 60 m, 0.53 mm ID, 3.00 µm (cat.# 10188)
Injector: Split
Detector: MS-Scan
Injector: Split
Detector: MS-Scan
Solvent Mixture #3 on Rtx-200
GC_CH00342

Column: Rtx-200, 60 m, 0.53 mm ID, 3.00 µm (cat.# 15088)
Injector: Split
Detector: MS-Scan
Injector: Split
Detector: MS-Scan
Alcohols Stabilwax
GC_CH00288B

Column: Stabilwax, 60 m, 0.53 mm ID, 1.00 µm (cat.# 10658)
Injector: Split
Detector: MS-Scan
Injector: Split
Detector: MS-Scan
Solvent Mixture #3 on Stabilwax
GC_CH00343

Column: Stabilwax, 60 m, 0.53 mm ID, 1.00 µm (cat.# 10658)
Injector: Split
Detector: MS-Scan
Injector: Split
Detector: MS-Scan
Glycols on Rtx-200
GC_CH00326

Column: Rtx-200, 60 m, 0.53 mm ID, 3.00 µm (cat.# 15088)
Injector: Split
Detector: FID
Injector: Split
Detector: FID
Glycols on Rtx-BAC Plus 1 and 2 Column Set
GC_CF1163

Column: Rtx-BAC Plus 1 30 m, 0.32 mm ID, 1.8 µm (cat.# 18004), and Rtx-BAC Plus 2 30 m, 0.32 mm ID, 0.6 µm (cat.# 18006), using Rxi guard column 5 m, 0.32 mm ID (cat.# 10039), with universal “Y” Press-Tight connector (cat.# 20405-261)
Injector: Split
Detector: FID
Injector: Split
Detector: FID
Glycols on Rtx-BAC1 & Rtx-BAC2
GC_EV00474

Column: Rtx-BAC1 30 m, 0.32 mm ID, 1.80 µm (cat.# 18003), and Rtx-BAC2 30 m, 0.32 mm ID, 1.20 µm (cat.# 18002)
Injector: Split
Detector: FID
Injector: Split
Detector: FID
Custom Residual Solvent Mix on Rxi-624Sil MS (using conditions from Pro ezGC)
GC_PH1150

Column: Rxi-624Sil MS, 20 m, 0.18 mm ID, 1.00 µm (cat.# 13865)
Injector: Split
Detector: FID
Injector: Split
Detector: FID
Cleaning Solvents on Rtx-Wax
GC_FF00644

Column: Rtx-Wax, 30 m, 0.32 mm ID, 0.25 µm (cat.# 12424)
Injector: Split
Detector: FID
Injector: Split
Detector: FID
Column Comparison: Limit of Ethylene Glycol and Diethylene Glycol in Propylene Glycol
GC_PH1151

Column: Rxi-624Sil MS (see notes), 30 m, 0.32 mm ID, 1.80 µm (cat.# 13870)
Injector: Split
Detector: FID
Injector: Split
Detector: FID
Glycols on Rtx-Wax
GC_EV00444

Column: Rtx-Wax, 30 m, 0.53 mm ID, 1.00 µm (cat.# 12455)
Injector: Direct
Detector: FID
Injector: Direct
Detector: FID
Glycols on Rtx-200
GC_EV00445

Column: Rtx-200, 30 m, 0.53 mm ID, 1.00 µm (cat.# 15055)
Injector: Direct
Detector: FID
Injector: Direct
Detector: FID
Cleaning Solvents on Rtx-VMS
GC_FF00645

Column: Rtx-VMS, 60 m, 0.25 mm ID, 1.40 µm (cat.# 19916)
Injector: Split
Detector: FID
Injector: Split
Detector: FID
Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.