share:

Restek Searchable Chromatogram Library

Enter a compound, synonym, CAS #, compound class, column name, or keyword below.

Examples:
1,4-dioxane
123-91-1, pyrene and chrysene
semivolatiles and rxi5silms
8270

You are currently filtering on:

Limonene[x]

Enter more terms to filter the results further.

Rosemary Oil on Rxi-5Sil MS

GC_FF1311

More Details

Rosemary Oil on Rtx-Wax

GC_FF1299

More Details

Solvent Mixture #1 on Rtx-1

GC_CH00335

More Details

Solvent Mixture #1 on Rtx-200

GC_CH00336

More Details

Solvent Mixture #1 on Stabilwax

GC_CH00337

More Details

Solvent Mixture #2 on Rtx-1

GC_CH00338

More Details

Solvent Mixture #2 on Rtx-200

GC_CH00339

More Details

Solvent Mixture #2 on Stabilwax

GC_CH00340

More Details

Solvent Mixture #3 on Rtx-1

GC_CH00341

More Details

Solvent Mixture #3 on Rtx-200

GC_CH00342

More Details

Solvent Mixture #3 on Stabilwax

GC_CH00343

More Details

Cleaning Solvents on Rtx-Wax

GC_FF00644

More Details

Lemon Oil on Rtx-5

GC_FF00138

More Details

Citronella Java Oil on Rtx-1

GC_FF00144

More Details

Citronella Java Oil Stabilwax

GC_FF00145

More Details

Lemon Oil on Rt-βDEXsm

GC_FF00146

More Details

Rosemary Oil on Rt-βDEXsm

GC_FF00147

More Details

Cleaning Solvents on Rtx-VMS

GC_FF00645

More Details

Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us