Restek Searchable Chromatogram Library

You've Selected:

Market Area:
Petroleum & Petrochemical
Clear All Selections

Enter a compound, synonym, CAS #, compound class, column name, or keyword below.

Examples:
1,4-dioxane
123-91-1, pyrene and chrysene
semivolatiles and rxi5silms
8270

You are currently filtering on:

ovi[x]

Enter more terms to filter the results further.

Thiophene in Benzene on Rtx-Wax

GC_PC1357

Column: Rtx-Wax, 30 m, 0.32 mm ID, 1.00 µm (cat.# 12454)
Injector: Split
Detector: SCD

Alkylate Standard on Rtx-DHA 50 by Method D5134-13

GC_PC1319

Column: Rtx-DHA-50, 50 m, 0.20 mm ID, 0.50 µm (cat.# 10147)
Injector: Split
Detector: FID

Detailed Hydrocarbon Analysis (DHA) on Rtx-DHA-100

GC_PC1284

Column: Rtx-DHA-100, 100 m, 0.25 mm ID, 0.50 µm (cat.# 10148), using Rtx-5 DHA tuning column 2-5 m, 0.25 mm ID (cat.# 10165), with universal Press-Tight connectors (cat.# 20429)
Injector: Split
Detector: FID

PAHs in Sediment Extract on Rxi-PAH (Sampled From Spring Creek, PA)

GC_EV1329

Column: Rxi-PAH, 60 m, 0.25 mm ID, 0.10 µm (cat.# 49317)
Injector: Split
Detector: TOFMS

PAHs in Sediment Extract on Rxi-PAH (Sampled From Spring Creek, PA)

GC_EV1330

Column: Rxi-PAH, 60 m, 0.25 mm ID, 0.10 µm (cat.# 49317)
Injector: Split
Detector: TOFMS

PAHs in Sediment Extract on Rxi-PAH (Sampled From Spring Creek, PA)

GC_EV1331

Column: Rxi-PAH, 60 m, 0.25 mm ID, 0.10 µm (cat.# 49317)
Injector: Split
Detector: TOFMS

PAHs in Sediment Extract on Rxi-PAH (Sampled From Spring Creek, PA)

GC_EV1332

Column: Rxi-PAH, 60 m, 0.25 mm ID, 0.10 µm (cat.# 49317)
Injector: Split
Detector: TOFMS

Stir Bar Sorptive Extraction Cleaned Up Sample - QuEChERS Extract of NIST SRM Mussel (Rxi-17Sil MS and Rxi-1ms, m/z 178)

GC_EV1232

Column: Rxi-17Sil MS 15 m, 0.25 mm ID, 0.25 µm (cat.# 14120)Rxi-1ms 0.7 m, 0.15 mm ID, 0.15 µm (cat.# 43800)
Injector: Splitless
Detector: TOFMS

Stir Bar Sorptive Extraction Cleaned Up Sample - QuEChERS Extract of NIST SRM Mussel (Rxi17Sil MS and Rxi-1ms)

GC_EV1231

Column: Rxi-17Sil MS 15 m, 0.25 mm ID, 0.25 µm (cat.# 14120)Rxi-1ms 0.7 m, 0.15 mm ID, 0.15 µm (cat.# 43800)
Injector: Splitless
Detector: TOFMS

GCxGC Contour Plot of Riser Pipe Oil in 2010 Gulf Oil Spill (Rxi-17Sil MS and Rxi-1ms)

GC_EV1230

Column: Rxi-17Sil MS 30 m, 0.25 mm ID, 0.25 µm (cat.# 14123)Rxi-1ms 1.2 m, 0.15 mm ID, 0.15 µm (cat.# 43800)
Injector: Splitless
Detector: TOFMS

GCxGC Contour Plot of Riser Pipe Oil in 2010 Gulf Oil Spill (Rxi-17Sil MS and Rxi-1ms)

GC_EV1229

Column: Rxi-17Sil MS 30 m, 0.25 mm ID, 0.25 µm (cat.# 14123)Rxi-1ms 1.2 m, 0.15 mm ID, 0.15 µm (cat.# 43800)
Injector: Splitless
Detector: TOFMS

Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us