share:

Restek Searchable Chromatogram Library

Enter a compound, synonym, CAS #, compound class, column name, or keyword below.

Examples:
1,4-dioxane
123-91-1, pyrene and chrysene
semivolatiles and rxi5silms
8270

You are currently filtering on:

oxygenates[x]

Enter more terms to filter the results further.

Simulated Distillation of Gasoline on MXT-1 (ASTM D7096-16)

GC_PC1326

Column: MXT-1, 30 m, 0.53 mm ID, 5.00 µm (cat.# 70179)
Injector: Split
Detector: FID

Simulated Distillation of Gasoline with Oxygenates on MXT-1 (ASTM D7096-16)

GC_PC1327

Column: MXT-1, 30 m, 0.53 mm ID, 5.00 µm (cat.# 70179)
Injector: Split
Detector: FID

Simulated Distillation of Gasoline on MXT-1 (ASTM D7096-16)

GC_PC1328

Column: MXT-1, 15 m, 0.53 mm ID, 5.00 µm (cat.# 70177)
Injector: Split
Detector: FID

SPME Arrow vs. Traditional SPME Fiber

GC_EV1439

Column: Rtx-VMS, 30 m, 0.25 mm ID, 1.40 µm (cat.# 19915)
Injector: Split
Detector: MS-Scan

Oxygenates on Rtx-VMS

GC_EV00847

Column: Rtx-VMS, 30 m, 0.25 mm ID, 1.40 µm (cat.# 19915)
Injector: Purge and Trap Split
Detector: MS-Scan

Petroleum Oxygenates (MTBE) on Rtx-1

GC_PC00197

Column: Rtx-1, 60 m, 0.53 mm ID, 5.00 µm (cat.# 10183)
Injector: Direct
Detector: FID

Petroleum Oxygenates (ASTM D4815) on TCEP (Micropacked) & Rtx-1

GC_PC00194

Column: 20% TCEP on 80/100 Chromosorb PAW 0.56 m, 0.75 mm ID (cat.# 19040), and Rtx-1 (connected in series) 30 m, 0.53 mm ID, 3.00 µm (cat.# 10185)
Injector: Split
Detector: FID

Volatile Organics US EPA Method 8260B on Rtx-VMS

GC_EV00640

Column: Rtx-VMS, 40 m, 0.18 mm ID, 1.00 µm (cat.# 49915)
Injector: Purge and Trap Split
Detector: 5973 GC/MS w/ turbomolecular pump

Petroleum Oxygenates on Stabilwax

GC_PC00196

Column: Stabilwax, 30 m, 0.53 mm ID, 1.00 µm (cat.# 10655)
Injector: Direct
Detector: FID

Gasoline Range Organics Oxygenates Rtx-VMS

GC_EV00679

Column: Rtx-VMS, 30 m, 0.25 mm ID, 1.40 µm (cat.# 19915)
Injector: Purge and Trap Split
Detector: MS-Scan

Volatile Organics by EPA 8260B & Oxygenates on Rtx-VMS

GC_EV00423

Column: Rtx-VMS, 60 m, 0.45 mm ID, 2.55 µm (cat.# 19909)
Injector: Purge and Trap Split
Detector: MS-Scan

Volatiles by EPA Method 8260 on Rxi-624Sil MS (30m, 0.25mm ID, 1.40µm)

GC_EV1169

Column: Rxi-624Sil MS, 30 m, 0.25 mm ID, 1.40 µm (cat.# 13868)
Injector: Purge and Trap Split
Detector: MS-Scan

Petroleum Oxygenates on Rt-TCEP

GC_PC00195

Column: Rt-TCEP, 60 m, 0.25 mm ID, 0.40 µm (cat.# 10999)
Injector: Split
Detector: FID

Volatile Organics by EPA Method 8260 (80ppb Standard) on Rtx-VMS

GC_EV00685

Column: Rtx-VMS, 30 m, 0.25 mm ID, 1.4 µm (cat.# 19915)
Injector: Purge and Trap Split
Detector: Agilent 5971A GC-MS

Fast Detailed Hydrocarbons Analysis (DHA) on Rtx-DHA-100/Rtx-5 DHA

GC_PC00774

Column: Rtx-DHA-100, 100 m, 0.25 mm ID, 0.50 µm (cat.# 10148), using Rtx-5 DHA tuning column* 2-5 m, 0.25 mm ID,
Injector: Split
Detector: FID

Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us