share:

Restek Searchable Chromatogram Library

Enter a compound, synonym, CAS #, compound class, column name, or keyword below.

Examples:
1,4-dioxane
123-91-1, pyrene and chrysene
semivolatiles and rxi5silms
8270

You are currently filtering on:

Pentachloroanisole[x]

Enter more terms to filter the results further.

GC Multiresidue Pesticide Standard #2-OCP on Rxi-5ms by GC-MS

GC_FS0601

Column: Rxi-5ms, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13423)
Injector: Split
Detector: MS-Scan

GCxGC-TOFMS Analysis of Multi-Pesticide Standard Using Rxi-5Sil MS and Rtx-200

GC_FF1241

Column: Rxi-5Sil MS 30 m, 0.25 mm ID, 0.25 µm (cat.# 13623)Rtx-200 1.3 m, 0.25 mm ID, 0.25 µm (cat.# 15124)
Injector: Splitless
Detector: MS-TOF

Chlorophenoxyacid Herbicides (methyl esters) US EPA Method 515 by GC/ECD on Rtx-440

GC_EV00756

Column: Rtx-440, 30 m, 0.32 mm ID, 0.25 µm (cat.# 12924)
Injector: Splitless
Detector: ECD

Chlorophenoxyacid Herbicides (methyl esters) US EPA Method 515 by GC/ECD on Rtx-CLPesticides2

GC_EV00755

Column: Rtx-CLPesticides2, 30 m, 0.32 mm ID, 0.25 µm (cat.# 11324)
Injector: Splitless
Detector: ECD

Chlorophenoxyacid Herbicides US EPA Method 8151 Rtx-CLPesticides & Rtx-CLPesticides2

GC_EV00091

Column: Rtx-CLPesticides 30 m, 0.32 mm ID, 0.50 µm (cat.# 11139), and Rtx-CLPesticides2 30 m, 0.32 mm ID, 0.25 µm (cat.# 11324)
Injector: Direct
Detector: ECD w/anode purge

Marijuana Pesticides by GCxGC on Rxi-5Sil MS and Rtx-200

GC_FF1205

Column: Rxi-5Sil MS 30 m, 0.25 mm ID, 0.25 µm (cat.# 13623)Rtx-200 1.3 m, 0.25 mm ID, 0.25 µm (cat.# 15020)
Injector: Splitless
Detector: TOFMS

Herbicides on Rtx-CLPesticides & Rtx-CLPesticides2

GC_EV00971

Column: Rtx-CLPesticides2 30 m, 0.32 mm ID, 0.25 µm (cat.# 11324), and Rtx-CLPesticides 30 m, 0.32 mm ID, 0.32 µm (cat.# 11141), using Rxi deactivated guard column 5 m, 0.32 mm ID (cat.# 10039), with universal “Y” Press-Tight connector (cat.# 20405-261)
Injector: Splitless
Detector: Micro_ECD

QuEChERS Extracts of Tylenol Spiked with Anisoles and TBA on Rxi-5Sil MS

GC_GN1152

Column: Rxi-5Sil MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13623)
Injector: Splitless
Detector: TOFMS

Mass Spectra of Pentachloroanisole QuEChERS Extracts of Tylenol Spiked with Anisoles and TBA on Rxi-5Sil MS

GC_GN1153

Column: Rxi-5Sil MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13623)
Injector: Splitless
Detector: TOFMS

Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us