Restek Searchable Chromatogram Library

You've Selected:

Market Area:
Petroleum & Petrochemical
Clear All Selections

Enter a compound, synonym, CAS #, compound class, column name, or keyword below.

Examples:
1,4-dioxane
123-91-1, pyrene and chrysene
semivolatiles and rxi5silms
8270

You are currently filtering on:

quadrupole[x]

Enter more terms to filter the results further.

Regulated Carcinogenic Aryl Amines Resulting From Reductive Cleavage of Azo Dyes on Rxi-35Sil MS

GC_QA0095

Column: Rxi-35Sil MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13823)
Injector: Split
Detector: MS-Scan

High Speed GC-MS of Carcinogenic Aryl Amines Resulting From Reductive Cleavage of Azo Dyes on Rxi-35Sil MS (Scan Mode)

GC_QA0096

Column: Rxi-35Sil MS, 15 m, 0.25 mm ID, 0.25 µm (cat.# 13820)
Injector: Split
Detector: MS-Scan

High Speed GC-MS-SIM of Carcinogenic Aryl Amines Resulting From Reductive Cleavage of Azo Dyes on Rxi-35Sil MS (SIM Mode)

GC_QA0098

Column: Rxi-35Sil MS, 15 m, 0.25 mm ID, 0.25 µm (cat.# 13820)
Injector: Split
Detector: MS-SIM

Glycol Ethers of Regulatory Importance on Rxi-1301Sil MS

GC_PC1280

Column: Rxi-1301Sil MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 16094)
Injector: Split
Detector: MS-Scan

Comprehensive Glycol Ether Mix on Rxi-1301Sil MS

GC_PC1279

Column: Rxi-1301Sil MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 16094)
Injector: Split
Detector: MS-Scan

Glycol Ethers of Regulatory Importance on Rtx-624

GC_PC1282

Column: Rtx-624, 30 m, 0.25 mm ID, 1.40 µm (cat.# 10968)
Injector: Split
Detector: MS-Scan

Custom Solvents Mix on Stabilwax-MS

GC_GN1163

Column: Stabilwax-MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 10673)
Injector: Split
Detector: MS-Scan

Alcohols and Acetates on Stabilwax-MS

GC_FF1224

Column: Stabilwax-MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 10673)
Injector: Split
Detector: MS-Scan

Volatile Organics by EPA 8260B on Rtx-VMS

GC_EV00428

Column: Rtx-VMS, 20 m, 0.18 mm ID, 1.00 µm (cat.# 49914)
Injector: Purge and Trap Split
Detector: MS-Scan

Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us