Restek Searchable Chromatogram Library

You've Selected:

Market Area:
Environmental
Clear All Selections

Enter a compound, synonym, CAS #, compound class, column name, or keyword below.

Examples:
1,4-dioxane
123-91-1, pyrene and chrysene
semivolatiles and rxi5silms
8270

You are currently filtering on:

raptor[x]

Enter more terms to filter the results further.

Perfluorinated Alkyl Acids (PFBS, PFOA, PFOS, and HFPO-DA/GenX) on Raptor C18 5 μm

LC_EV0553

Column: Raptor C18 (cat.# 9304552), Dimensions:50 mm x 2.1 mm ID, Particle Size: 5 µm, Pore Size: 90 Å, Temperature: 40 °C
Detector: MS/MS

16-Hr Laboratory Air Sample with radiello 165

LC_AR0508

Column: Raptor C18 (cat.# 9304A65), Dimensions:150 mm x 4.6 mm ID, Particle Size: 2.7 µm, Pore Size: 90 Å, Temperature: 30 °C
Detector: UV/Vis

Perfluorinated Alkyl Acids on Raptor C18 by LC-MS/MS for EPA Method 537

LC_EV0548

Column: Raptor C18 (cat.# 9304552), Dimensions:50 mm x 2.1 mm ID, Particle Size: 5 µm, Pore Size: 90 Å, Temperature: 40 °C
Detector: MS/MS

Perfluorinated Compounds (PFCs) on Raptor C18 (1.8 μm)

LC_EV0540

Column: Raptor C18 (cat.# 9304252), Dimensions:50 mm x 2.1 mm ID, Particle Size: 1.8 µm, Pore Size: 90 Å, Temperature: 40 °C
Detector: MS/MS

Perfluorinated Compounds (PFCs) on Raptor C18 (1.8 μm)

LC_EV0547

Column: Raptor C18 (cat.# 9304252), Dimensions:50 mm x 2.1 mm ID, Particle Size: 1.8 µm, Pore Size: 90 Å, Temperature: 40 °C
Detector: MS/MS

Pharmaceuticals and Personal Care Products (PPCPs) on Raptor Biphenyl (1.8 μm)

LC_EV0539

Column: Raptor Biphenyl (cat.# 9309252), Dimensions:50 mm x 2.1 mm ID, Particle Size: 1.8 µm, Pore Size: 90 Å, Temperature: 40 °C
Detector: MS/MS

Bisphenols on Raptor Biphenyl 1.8 μm

LC_FS0518

Column: Raptor Biphenyl (cat.# 9309252), Dimensions:50 mm x 2.1 mm ID, Particle Size: 1.8 µm, Pore Size: 90 Å, Temperature: 25 °C
Detector: MS/MS

Paraquat and Diquat on Raptor HILIC-Si

LC_FS0512

Column: Raptor HILIC-Si (cat.# 9310A52), Dimensions:50 mm x 2.1 mm ID, Particle Size: 2.7 µm, Pore Size: 90 Å, Temperature: 45 °C
Detector: MS/MS

Perfluorooctanoic Acid (PFOA) and Perfluorooctanesulfonic Acid (PFOS) on Raptor C18 by LC-MS/MS

LC_EV0536

Column: Raptor C18 (cat.# 9304512), Dimensions:100 mm x 2.1 mm ID, Particle Size: 5 µm, Pore Size: 90 Å, Temperature: 40 °C
Detector: MS/MS

Phenylurea Herbicides on Raptor C18

LC_EV0533

Column: Raptor C18 (cat.# 9304565), Dimensions:150 mm x 4.6 mm ID, Particle Size: 5 µm, Temperature: 30 °C
Detector: PDA

Aldehyde-Ketone-DNPH TO-11A Calibration Mix on Raptor C18

LC_EV0532

Column: Raptor C18 (cat.# 9304A65), Dimensions:150 mm x 4.6 mm ID, Particle Size: 2.7 µm, Pore Size: 90 Å, Temperature: 30 °C
Detector: Waters Acquity PDA

Explosives on Raptor ARC-18 by EPA Method 8330B

LC_EV0530

Column: Raptor ARC-18 (cat.# 9314A1E), Dimensions:100 mm x 3.0 mm ID, Particle Size: 2.7 µm, Temperature: 35 °C
Detector: Shimadzu Prominence SPD-M20A Diode array

Explosives on Raptor Biphenyl by EPA Method 8330B

LC_EV0531

Column: Raptor Biphenyl (cat.# 9309A65), Dimensions:150 mm x 4.6 mm ID, Particle Size: 2.7 µm, Temperature: 35 °C
Detector: Shimadzu Prominence SPD-M20A Diode array

CARB 1004 Aldehyde/Ketone-DNPH Calibration Standard on Raptor ARC-18

LC_EV0529

Column: Raptor ARC-18 (cat.# 9314A1E), Dimensions:100 mm x 3.0 mm ID, Particle Size: 2.7 µm, Temperature: 40 °C
Detector: Waters Acquity PDA

Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.