Restek Searchable Chromatogram Library

You've Selected:

Market Area:
Foods, Flavors & Fragrances
Clear All Selections

Enter a compound, synonym, CAS #, compound class, column name, or keyword below.

Examples:
1,4-dioxane
123-91-1, pyrene and chrysene
semivolatiles and rxi5silms
8270

You are currently filtering on:

turboionspray[x]

Enter more terms to filter the results further.

Aflatoxins on Raptor ARC-18 by LC-MS/MS

LC_FF0538

Column: Raptor ARC-18 (cat.# 9314A5E), Dimensions:50 mm x 3.0 mm ID, Particle Size: 2.7 µm, Temperature: 45 °C
Detector: Applied Biosystems 4000 QTRAP® LC-MS/MS system

Fat-Soluble Vitamins on Raptor ARC-18 by LC-MS/MS

LC_FF0537

Column: Raptor ARC-18 (cat.# 9314A12), Dimensions:100 mm x 2.1 mm ID, Particle Size: 2.7 µm, Temperature: 40 °C
Detector: ABSCIEX API 4000

LC Multiresidue Pesticide Standard #4 on Ultra Aqueous C18 by LC-MS/MS

LC_FF0520

Column: Ultra Aqueous C18 (cat.# 9178312), Dimensions:100 mm x 2.1 mm ID, Particle Size: 3 µm, Pore Size: 100 Å, Temperature: 50 °C
Detector: AB SCIEX API 4000 LC-MS/MS

LC Multiresidue Pesticide Standard #3 on Ultra Aqueous C18 by LC-MS/MS

LC_FF0519

Column: Ultra Aqueous C18 (cat.# 9178312), Dimensions:100 mm x 2.1 mm ID, Particle Size: 3 µm, Pore Size: 100 Å, Temperature: 50 °C
Detector: AB SCIEX API 4000 LC-MS/MS

LC Multiresidue Pesticide Standard #2 on Ultra Aqueous C18 by LC-MS/MS

LC_FF0518

Column: Ultra Aqueous C18 (cat.# 9178312), Dimensions:100 mm x 2.1 mm ID, Particle Size: 3 µm, Pore Size: 100 Å, Temperature: 50 °C
Detector: AB SCIEX API 4000 LC-MS/MS

LC Multiresidue Pesticide Standard #6 on Ultra Aqueous C18 by LC-MS/MS

LC_FF0522

Column: Ultra Aqueous C18 (cat.# 9178312), Dimensions:100 mm x 2.1 mm ID, Particle Size: 3 µm, Pore Size: 100 Å, Temperature: 50 °C
Detector: AB SCIEX API 4000 LC-MS/MS

LC Multiresidue Pesticide Standard #7 on Ultra Aqueous C18 by LC-MS/MS

LC_FF0523

Column: Ultra Aqueous C18 (cat.# 9178312), Dimensions:100 mm x 2.1 mm ID, Particle Size: 3 µm, Pore Size: 100 Å, Temperature: 50 °C
Detector: AB SCIEX API 4000 LC-MS/MS

LC Multiresidue Pesticide Standard #8 on Ultra Aqueous C18 by LC-MS/MS

LC_FF0524

Column: Ultra Aqueous C18 (cat.# 9178312), Dimensions:100 mm x 2.1 mm ID, Particle Size: 3 µm, Pore Size: 100 Å, Temperature: 50 °C
Detector: AB SCIEX API 4000 LC-MS/MS

LC Multiresidue Pesticide Standard #9 on Ultra Aqueous C18 by LC-MS/MS

LC_FF0525

Column: Ultra Aqueous C18 (cat.# 9178312), Dimensions:100 mm x 2.1 mm ID, Particle Size: 3 µm, Pore Size: 100 Å, Temperature: 50 °C
Detector: AB SCIEX API 4000 LC-MS/MS

LC Multiresidue Pesticide Standard #1 on Ultra Aqueous C18 by LC-MS/MS

LC_FF0517

Column: Ultra Aqueous C18 (cat.# 9178312), Dimensions:100 mm x 2.1 mm ID, Particle Size: 3 µm, Pore Size: 100 Å, Temperature: 50 °C
Detector: AB SCIEX API 4000 LC-MS/MS

LC Multiresidue Pesticide Standard #10 on Ultra Aqueous C18 by LC-MS/MS

LC_FF0526

Column: Ultra Aqueous C18 (cat.# 9178312), Dimensions:100 mm x 2.1 mm ID, Particle Size: 3 µm, Pore Size: 100 Å, Temperature: 50 °C
Detector: AB SCIEX API 4000 LC-MS/MS

LC Multiresidue Pesticide Standard #5 on Ultra Aqueous C18 by LC-MS/MS

LC_FF0521

Column: Ultra Aqueous C18 (cat.# 9178312), Dimensions:100 mm x 2.1 mm ID, Particle Size: 3 µm, Pore Size: 100 Å, Temperature: 50 °C
Detector: AB SCIEX API 4000 LC-MS/MS

Pesticide Residue Analysis in Kale by LC-MS/MS on Ultra Aqueous C18

LC_FF0516

Column: Ultra Aqueous C18 (cat.# 9178312), Dimensions:100 mm x 2.1 mm ID, Particle Size: 3 µm, Pore Size: 100 Å, Temperature: 50 °C
Detector: ABSCIEX MS/MS

Incurred Pesticides in Red Bell Pepper QuEChERS Extract on Ultra Aqueous C18

LC_FF0515

Column: Ultra Aqueous C18 (cat.# 9178312), Dimensions:100 mm x 2.1 mm ID, Particle Size: 3 µm, Pore Size: 100 Å
Detector: AB SCIEX API 4000 LC/MS/MS System

Pesticides on Ultra Aqueous C18

LC_FF0490

Column: Ultra Aqueous C18 (cat.# 9178312), Dimensions:100 mm x 2.1 mm ID, Particle Size: 3 µm, Pore Size: 100 Å, Temperature: 35 °C
Detector: Applied Biosystems 4000 QTRAP® LC-MS/MS system

Pesticides on Ultra Aqueous C18

LC_FF0490A

Column: Ultra Aqueous C18 (cat.# 9178312), Dimensions:100 mm x 2.1 mm ID, Particle Size: 3 µm, Pore Size: 100 Å, Temperature: 35 °C
Detector: Applied Biosystems 4000 QTRAP® LC-MS/MS system

Pesticides on Ultra Aqueous C18

LC_FF0490B

Column: Ultra Aqueous C18 (cat.# 9178312), Dimensions:100 mm x 2.1 mm ID, Particle Size: 3 µm, Pore Size: 100 Å, Temperature: 35 °C
Detector: Applied Biosystems 4000 QTRAP® LC-MS/MS system

Pesticides on Pinnacle DB Aqueous C18

LC_FF0479A

Column: Pinnacle DB Aqueous C18 (cat.# 9418252), Dimensions:50 mm x 2.1 mm ID, Particle Size: 1.9 µm, Pore Size: 140 Å, Temperature: 35 °C
Detector: Applied Biosystems 4000 QTRAP® LC-MS/MS system

Pesticides on Pinnacle DB Aqueous C18

LC_FF0479B

Column: Pinnacle DB Aqueous C18 (cat.# 9418252), Dimensions:50 mm x 2.1 mm ID, Particle Size: 1.9 µm, Pore Size: 140 Å, Temperature: 35 °C
Detector: Applied Biosystems 4000 QTRAP® LC-MS/MS system

Pesticides on Pinnacle DB Aqueous C18

LC_FF0479C

Column: Pinnacle DB Aqueous C18 (cat.# 9418252), Dimensions:50 mm x 2.1 mm ID, Particle Size: 1.9 µm, Pore Size: 140 Å, Temperature: 35 °C
Detector: Applied Biosystems 4000 QTRAP® LC-MS/MS system

Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us