Antipsychotics and Antidepressants in Human Urine on Raptor Biphenyl by LC-MS/MS

LC_CF0749

Column: Raptor Biphenyl (cat.# 9309A5E), Dimensions:50 mm x 3.0 mm ID, Particle Size: 2.7 µm, Pore Size: 90 Å, Temperature: 30 °C
Detector: MS/MS

d & l Amphetamines (DNPA Derivatives) in Urine by LC-MS/MS

LC_CF0737

Column: Raptor C18 (cat.# 9304A12), Dimensions:100 mm x 2.1 mm ID, Particle Size: 2.7 µm, Pore Size: 90 Å, Temperature: 35 °C
Detector: MS/MS

EtG/EtS in UTAK EtG Plus Level 1 Urine Control on Raptor EtG/EtS by LC-MS/MS

LC_CF0726

Column: Raptor EtG/EtS (cat.# 9325A12), Dimensions:100 mm x 2.1 mm ID, Particle Size: 2.7 µm, Pore Size: 90 Å, Temperature: 35 °C
Detector: MS/MS

Creatine and Creatinine in Human Urine on Raptor HILIC-Si by LC-MS/MS

LC_CF0723

Column: Raptor HILIC-Si (cat.# 9310A52), Dimensions:50 mm x 2.1 mm ID, Particle Size: 2.7 µm, Pore Size: 90 Å, Temperature: 40 °C
Detector: MS/MS

Fentanyl and Analogues in Urine on Raptor Biphenyl by LC-MS/MS

LC_CF0715

Column: Raptor Biphenyl (cat.# 9309552), Dimensions:50 mm x 2.1 mm ID, Particle Size: 5 µm, Pore Size: 90 Å, Temperature: 40 °C
Detector: MS/MS

Ethyl Glucuronide (EtG) and Ethyl Sulfate (EtS) in Urine on Raptor EtG/EtS

LC_CF0704

Column: Raptor EtG/EtS (cat.# 9325A12), Dimensions:100 mm x 2.1 mm ID, Particle Size: 2.7 µm, Pore Size: 90 Å, Temperature: 35 °C
Detector: MS/MS

Catecholamines and Metabolites in Human Urine on Raptor Biphenyl by LC-MS/MS

LC_CF0703

Column: Raptor Biphenyl (cat.# 9309A62), Dimensions:150 mm x 2.1 mm ID, Particle Size: 2.7 µm, Pore Size: 90 Å, Temperature: 30 °C
Detector: MS/MS

Cortisol and Cortisone in Extracted Female Human Urine on Raptor Biphenyl by LC-MS/MS

LC_CF0697

Column: Raptor Biphenyl (cat.# 9309A52), Dimensions:50 mm x 2.1 mm ID, Particle Size: 2.7 µm, Pore Size: 90 Å, Temperature: 40 °C
Detector: MS/MS

The Analysis of Morphine & Metabolites in Urine without Hydrolysis on Force Biphenyl

LC_CF0680

Column: Force Biphenyl (cat.# 9629252), Dimensions:50 mm x 2.1 mm ID, Particle Size: 1.8 µm, Temperature: 40 °C
Detector: MS/MS

Vanillylmandelic Acid, Homovanillic Acid, and 5-Hydroxyindoleacetic Acid in Human Urine (Quantitative Control Level 1) on Raptor Biphenyl

LC_CF0661

Column: Raptor Biphenyl (cat.# 9309512), Dimensions:100 mm x 2.1 mm ID, Particle Size: 5 µm, Pore Size: 90 Å, Temperature: 30 °C
Detector: MS/MS

Combined Analysis of Synthetic Cannabinoids & Metabolites in Urine by LC-MS/MS on Raptor Biphenyl

LC_CF0613

Column: Raptor Biphenyl (cat.# 9309A5E), Dimensions:50 mm x 3.0 mm ID, Particle Size: 2.7 µm
Detector: MS/MS

Synthetic Cannabinoids in Urine by LC-MS/MS on Raptor Biphenyl

LC_CF0612

Column: Raptor Biphenyl (cat.# 9309A5E), Dimensions:50 mm x 3.0 mm ID, Particle Size: 2.7 µm
Detector: MS/MS

Nicotine-Related Compounds in Urine on Raptor Biphenyl by LC-MS/MS

LC_CF0606

Column: Raptor Biphenyl (cat.# 9309512), Dimensions:100 mm x 2.1 mm ID, Particle Size: 5 µm, Pore Size: 90 Å, Temperature: 30 °C
Detector: MS/MS

Fentanyl, Metabolite, and Analogues in Urine on Raptor Biphenyl by LC-MS/MS

LC_CF0591

Column: Raptor Biphenyl (cat.# 9309552), Dimensions:50 mm x 2.1 mm ID, Particle Size: 5 µm, Temperature: 30 °C
Detector: MS/MS

Naltrexone and 6-β-Naltrexol in Urine on Raptor Biphenyl by LC-MS/MS

LC_CF0588

Column: Raptor Biphenyl (cat.# 9309552), Dimensions:50 mm x 2.1 mm ID, Particle Size: 5 µm, Pore Size: 90 Å, Temperature: 30 °C
Detector: MS/MS

Synthetic Cannabinoid Metabolites in Urine on Raptor Biphenyl by LC-MS/MS

LC_CF0585

Column: Raptor Biphenyl (cat.# 9309A5E), Dimensions:50 mm x 3.0 mm ID, Particle Size: 2.7 µm, Temperature: 30 °C
Detector: Waters Xevo TQ-S

Norbuprenorphine & Buprenorphine in Urine on Raptor Biphenyl by LC-MS/MS

LC_CF0580

Column: Raptor Biphenyl (cat.# 9309A5E), Dimensions:50 mm x 3.0 mm ID, Particle Size: 2.7 µm, Temperature: 30 °C
Detector: AB SCIEX API 4000 MS/MS

Synthetic Cannabinoids in Urine on Raptor Biphenyl by LC-MS/MS

LC_CF0584

Column: Raptor Biphenyl (cat.# 9309A5E), Dimensions:50 mm x 3.0 mm ID, Particle Size: 2.7 µm, Temperature: 30 °C
Detector: Waters Xevo TQ-S

Benzodiazepines in Urine on Raptor Biphenyl by LC-MS/MS

LC_CF0581

Column: Raptor Biphenyl (cat.# 9309A5E), Dimensions:50 mm x 3.0 mm ID, Particle Size: 2.7 µm, Temperature: 40 °C
Detector: ABSCIEX API 4000 MS/MS

Therapeutic Drugs in Urine on Raptor Biphenyl by LC-MS/MS

LC_CF0579

Column: Raptor Biphenyl (cat.# 9309A5E), Dimensions:50 mm x 3.0 mm ID, Particle Size: 2.7 µm, Pore Size: 100 Å, Temperature: 40 °C
Detector: ABSCIEX API 4000 MS/MS

THC + Metabolites in Urine on Raptor Biphenyl by LC-MS/MS

LC_CF0583

Column: Raptor Biphenyl (cat.# 9309A5E), Dimensions:50 mm x 3.0 mm ID, Particle Size: 2.7 µm, Temperature: 40 °C
Detector: Waters Xevo TQ-S

Pain Panel in Urine on Raptor Biphenyl (50 x 3.0 mm) by LC-MS/MS

LC_CF0568

Column: Raptor Biphenyl (cat.# 9309A5E), Dimensions:50 mm x 3.0 mm ID, Particle Size: 2.7 µm, Temperature: 30 °C
Detector: AB SCIEX API 4000 MS/MS

100 ng/mL Benzodiazepines in Hydrolyzed Urine on Ultra Biphenyl by LC-MS/MS

LC_CF0525

Column: Ultra Biphenyl (cat.# 9109552), Dimensions:50 mm x 2.1 mm ID, Particle Size: 5 µm, Pore Size: 100 Å, Temperature: 40 °C
Detector: AB SCIEX API 4000 MS/MS

GHB (analyzed as GBL) in Urine on Rtx-5MS

GC_CF01038

Column: Rtx-5MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 12623)
Injector: Headspace - Syringe Split
Detector: MS-Scan

Comparison of Converted and Unconverted GHB on Rtx-BAC1

GC_CF01039

Column: Rtx-BAC1, 30 m, 0.32 mm ID, 1.80 µm (cat.# 18003)
Injector: Headspace - Syringe Split
Detector: FID

Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us