share:

This chromatogram may contain analytes that are synonyms of your search terms.

Organophosphorous Pesticides U.S. EPA Method 8141A on Rtx-OPPesticides & Rtx-OPPesticides2

Peaks
1.Dichlorvos
2.Hexamethylphosphoramide
3.Mevinphos
4.Trichlorfon
5.TEPP
6.Demeton-O
7.Tributyl phosphate (SS)
8.Thionazin
9.Ethoprop
10.Naled
11.Sulfotepp
12.Phorate
13.Dicrotophos
14.Monocrotophos
15.Demeton-S
16.Terbufos
17.Dimethoate
18.Diazinon
19.Dioxathion
20.Fonophos
21.Disulfoton
22.Phosphamidon isomer (breakdown product)
23.Dichlorofenthion
24.Phosphamidon
25.Chlorpyrifos methyl
26.Methyl parathion
Peaks
27.Ronnel
28.Aspon
29.Fenitrothion
30.Malathion
31.Chlorpyrifos
32.Trichloronate
33.Parathion-ethyl
34.Fenthion
35.Merphos
36.Chlorfenvinphos
37.Crotoxyphos
38.Stirofos
39.Prothiofos
40.Merphos oxone (breakdown product)
41.Ethion
42.Fensulfothion
43.Sulprofos
44.Carbophenothion
45.Famphur
46.Triphenyl phosphate (SS)
47.EPN
48.Phosmet
49.Leptophos
50.Tri-o-cresyl phosphate
51.Azinphos-methyl
52.Azinphos-ethyl
53.Coumaphos
image
GC_EV00394
ColumnsRtx-OPPesticides 30 m, 0.32 mm ID, 0.50 µm (cat.# 11239)
and Rtx-OPPesticides2 30 m, 0.32 mm ID, 0.32 µm (cat.# 11241)
SampleTriphenylphosphate (cat.# 32281)
Tributylphosphate (cat.# 32280)
8140/8141 OP pesticide calibration mix A (cat.# 32277)
8141 OP pesticide calibration mix B (cat.# 32278)
Conc.:100 ng/mL
Injection
Inj. Vol.:1 µL splitless (hold 1 min)
Liner:Siltek splitless taper (4 mm) (cat.# 20798-214.1)
Inj. Temp.:200 °C
Oven
Oven Temp.:80 °C (hold 0.5 min) to 280 °C at 12 °C/min (hold 10 min)
Carrier GasHe
Dead Time:1.03 min @ 80 °C
DetectorFPD @ 250 °C
NotesConstant pressure
Download PDF

RELATED CHROMATOGRAM LIBRARY SEARCHES

opp

,

opps

,

Pesticides

Printing tips! To print chromatograms full page, change the print settings in the print dialogue window of your PDF reader software: 1) "fit" or "fit to page", 2) "landscape" for wide chromatograms or "portrait" for tall chromatograms.


Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us