share:

Volatile Organics by EPA 8260B on Rtx-VMS

Peaks
1.Dichlorodifluoromethane
2.Chloromethane
3.Vinyl chloride
4.Bromomethane
5.Chloroethane
6.Trichlorofluoromethane
7.Ethanol (2,500 ppb)
8.1,1-Dichloroethene
9.Carbon disulfide (40 ppb)
10.Allyl chloride
11.Methylene chloride
12.Acetone
13.trans-1,2-Dichloroethene
14.tert-Butyl alcohol (100 ppb)
15.Methyl tert-butyl ether
16.Diisopropyl ether
17.1,1-Dichloroethane
18.Acrylonitrile
19.Vinyl acetate
20.Allyl alcohol (250 ppb)
21.Ethyl tert-butyl ether
22.cis-1,2-Dichloroethene
23.2,2-Dichloropropane
24.Bromochloromethane
25.Chloroform
26.Ethyl acetate
27.Methyl acrylate
28.Propargyl alcohol (500 ppb)
29.Dibromofluoromethane (SMC)
30.Tetrahydrofuran
31.Carbon tetrachloride
32.2-Butanone
33.1,1,1-Trichloroethane
34.1,1-Dichloropropene
35.Pentafluorobenzene (IS)
36.tert-Amyl Methyl ether
37.Benzene
38.Isobutyl alcohol (500 ppb)
39.1,2-Dichloroethane
40.Isopropyl acetate
41.1,4-Difluorobenzene (SMC)
42.Trichloroethene
43.Dibromomethane
44.Bromodichloromethane
45.1,2-Dichloropropane
46.Methyl methacrylate
47.n-Propyl acetate
48.2-Chloroethanol (2,500 ppb)
Peaks
49.cis-1,3-Dichloropropene
50.Toluene-d8 (SMC)
51.Toluene
52.4-Methyl-2-pentanone
53.Pyridine (250 ppb)
54.trans-1,3-Dichloropropene
55.Ethyl methacrylate
56.Tetrachloroethene
57.1,1,2-Trichloroethane
58.Dibromochloromethane
59.1,3-Dichloropropane
60.n-Butyl acetate
61.1,2-Dibromoethane
62.2-Hexanone
63.2-Picoline (250 ppb)
64.Ethylbenzene
65.Chlorobenzene-d5 (IS)
66.Chlorobenzene
67.1,1,1,2-Tetrachloroethane
68.m-Xylene
69.p-Xylene
70.o-Xylene
71.Styrene
72.Bromoform
73.Isopropylbenzene
74.4-Bromofluorobenzene (SMC)
75.n-Propylbenzene
76.1,1,2,2-Tetrachloroethane
77.Bromobenzene
78.1,3,5-Trimethylbenzene
79.2-Chlorotoluene
80.1,2,3-Trichloropropane
81.4-Chlorotoluene
82.tert-Butylbenzene
83.1,2,4-Trimethylbenzene
84.Pentachloroethane
85.sec-Butylbenzene
86.p-Isopropyltoluene
87.1,3-Dichlorobenzene
88.1,4-Dichlorobenzene-d4 (IS)
89.1,4-Dichlorobenzene
90.n-Butylbenzene
91.1,2-Dichlorobenzene
92.1,2-Dibromo-3-Chloropropane
93.Nitrobenzene (250 ppb)
94.Hexachlorobutadiene
95.1,2,4-Trichlorobenzene
96.Naphthalene
97.1,2,3-Trichlorobenzene
image
GC_EV00427
ColumnRtx-VMS, 60 m, 0.25 mm ID, 1.40 µm (cat.# 19916)
Sample
Diluent:water
Conc.: 10 ppb in 5mL RO water (unless noted); ketones 2.5x
Injectionpurge and trap split (split ratio 20:1)
Liner:1mm Split (cat.# 20973)
Inj. Temp.:220 °C
Purge and Trap
Instrument:Tekmar LCS 3100
Trap Type:Vocarb 3000
Purge: 11 min @ ambient, flow 40 mL/min
Dry Purge: 1 min, flow 40 mL/min
Desorb Preheat Temp.:245 °C
Desorb: 2 min @ 250 °C, flow 26 mL/min
Bake: 8 min @ 260 °C
Interface Connection:injection port
Transfer Line Tubing:Silcosteel Treated 0.53mm ID tubing(cat.# 20595)
Transfer Line Temp.:120 °C
Oven
Oven Temp.:60 °C (hold 2 min) to 180 °C at 12 °C/min to 225 °C at 45 °C/min (hold 6 min)
Carrier GasHe, constant flow
Flow Rate:1.3 mL/min
DetectorMS
Mode:Scan
Transfer Line Temp.:280 °C
Analyzer Type:Quadrupole
Tune Type:BFB
Ionization Mode:EI
Scan Range:35-300 amu
InstrumentHP6890 GC & 5973 MSD
NotesFor proper flows, adjust retention time of dichlorodifluoromethane to a retention time of 4.03 minutes @ 60C.
Download PDF

RELATED CHROMATOGRAM LIBRARY SEARCHES

Volatiles

,

VOC

,

trihalomethanes

,

VOA

,

ketones

,

alcohols

,

xylene

Printing tips! To print chromatograms full page, change the print settings in the print dialogue window of your PDF reader software: 1) "fit" or "fit to page", 2) "landscape" for wide chromatograms or "portrait" for tall chromatograms.


Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us