This site requires that Javascript be enabled. Please enable Javascript in your browser.
This chromatogram may contain analytes that are synonyms of your search terms.
Volatile Organics by EPA 8260B on Rtx-VMS
Peaks
1. Dichlorodifluoromethane
2. Chloromethane
3. Vinyl chloride
4. Bromomethane
5. Chloroethane
6. Trichlorofluoromethane
7. Ethanol (2,500 ppb)
8. 1,1-Dichloroethene
9. Carbon disulfide (40 ppb)
10. Allyl chloride
11. Methylene chloride
12. Acetone
13. trans- 1,2-Dichloroethene
14. Methyl tert- butyl ether
15. tert- Butyl alcohol (100 ppb)
16. Diisopropyl ether
17. 1,1-Dichloroethane
18. Acrylonitrile
19. Vinyl acetate
20. Allyl alcohol (250 ppb)
21. Ethyl tert- butyl ether
22. cis- 1,2-Dichloroethene
23. 2,2-Dichloropropane
24. Bromochloromethane
25. Chloroform
26. Ethyl acetate
27. Carbon tetrachloride
28. Methyl acrylate
29. Propargyl alcohol (500 ppb)
30. Dibromofluoromethane (SMC)
31. Tetrahydrofuran
32. 1,1,1-Trichloroethane
33. 2-Butanone
34. 1,1-Dichloropropene
35. Benzene
36. Pentafluorobenzene (IS)
37. tert- Amyl Methyl ether
38. 1,2-Dichloroethane
39. Isobutyl alcohol (500 ppb)
40. Isopropyl acetate
41. Trichloroethene
42. 1,4-Difluorobenzene (SMC)
43. Dibromomethane
44. 1,2-Dichloropropane
45. Bromodichloromethane
46. Methyl methacrylate
47. n- Propyl acetate
48. 2-Chloroethanol (2,500 ppb)
Peaks
49. cis- 1,3-Dichloropropene
50. Toluene-d8 (SMC)
51. Toluene
52. Pyridine (250 ppb)
53. Tetrachloroethene
54. 4-Methyl-2-pentanone
55. trans- 1,3-Dichloropropene
56. 1,1,2-Trichloroethane
57. Ethyl methacrylate
58. Dibromochloromethane
59. 1,3-Dichloropropane
60. 1,2-Dibromoethane
61. n- Butyl acetate
62. 2-Hexanone
63. 2-Picoline (250 ppb)
64. Chlorobenzene-d5 (IS)
65. Chlorobenzene
66. Ethylbenzene
67. 1,1,1,2-Tetrachloroethane
68. m- Xylene
69. p- Xylene
70. o- Xylene
71. Styrene
72. Bromoform
73. Isopropylbenzene
74. 4-Bromofluorobenzene (SMC)
75. Bromobenzene
76. n- Propylbenzene
77. 1,1,2,2-Tetrachloroethane
78. 2-Chlorotoluene
79. 1,3,5-Trimethylbenzene
80. 1,2,3-Trichloropropane
81. 4-Chlorotoluene
82. tert- Butylbenzene
83. Pentachloroethane
84. 1,2,4-Trimethylbenzene
85. sec- Butylbenzene
86. p- Isopropyltoluene
87. 1,3-Dichlorobenzene
88. 1,4-Dichlorobenzene-d4 (IS)
89. 1,4-Dichlorobenzene
90. n- Butylbenzene
91. 1,2-Dichlorobenzene
92. 1,2-Dibromo-3-Chloropropane
93. Nitrobenzene (250 ppb)
94. Hexachlorobutadiene
95. 1,2,4-Trichlorobenzene
96. Naphthalene
97. 1,2,3-Trichlorobenzene
GC_EV00428
Rtx-VMS, 20 m, 0.18 mm ID, 1.00 µm (cat.# 49914) Water 10 ppb in 5 mL RO water (unless noted); ketones 2.5X purge and trap split (split ratio 40:1) 1 mm split (cat.# 20973) 220 °C Tekmar LCS 3100 Vocarb 3000 11 min @ ambient, flow 40 mL/min 1 min, flow 40 mL/min 245 °C 2 min @ 250 °C, flow 40 mL/min 8 min @ 260 °C injection port Silcosteel-treated 0.53 mm ID tubing (cat.# 20595) 120 °C 50 °C (hold 4 min) to 100 °C at 18 °C/min (hold 0 min) to 230 °C at 40 °C/min (hold 3 min) He, constant flow 1.0 mL/min MS Scan 280 °C Quadrupole BFB EI 35-300 amu HP6890 GC & 5973 MSD For proper flows, adjust retention time of dichlorodifluoromethane to a retention time of 1.03 minutes @ 50 °C
Download PDF RELATED CHROMATOGRAM LIBRARY SEARCHES
Printing tips! To print chromatograms full page, change the print settings in the print dialogue window of your PDF reader software: 1) "fit" or "fit to page", 2) "landscape" for wide chromatograms or "portrait" for tall chromatograms.
Cookies allow for a variety of features that make your visit to Restek more enjoyable. By using this website, you agree to the use of cookies in accordance with our guidelines. For more information, see our privacy policy .