share:

This chromatogram may contain analytes that are synonyms of your search terms.

Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (20m, 0.18mm ID, 0.18µm)

Peaks
1.1,4-Dioxane
2.N-Nitrosodimethylamine
3.Pyridine
4.2-Fluorophenol (SS)
5.Phenol-d6- (SS)
6.Phenol
7.Aniline
8.Bis(2-chloroethyl) ether
9.2-Chlorophenol
10.1,3-Dichlorobenzene
11.1,4-dichlorobenzene-d4 (IS)
12.1,4-Dichlorobenzene
13.Benzyl alcohol
14.1,2-Dichlorobenzene
15.2-Methylphenol
16.Bis(2-chloroisopropyl) ether
17.4-methylphenol/3-methylphenol
18.N-Nitrosodi-N-propylamine
19.Hexachloroethylene
20.nitrobenzene-d5 (SS)
21.Nitrobenzene
22.Isophorone
23.2-Nitrophenol
24.2,4-Dimethylphenol
25.Bis(2-chloroethoxy)methane
26.Benzoic acid
27.2,4-Dichlorophenol
28.1,2,4-Trichlorobenzene
29.Naphthalene-d8 (IS)
30.Naphthalene
31.4-Chloroaniline
32.Hexachlorobutadiene
33.4-Chloro-3-methylphenol
34.2-Methylnaphthalene
35.1-Methylnaphthalene
36.Hexachlorocyclopentadiene
37.2,4,6-Trichlorophenol
38.2,4,5-Trichlorophenol
39.2-Fluorobiphenyl (SS)
40.2-Chloronaphthalene
41.2-Nitroaniline
42.1,4-Dinitrobenzene
43.Dimethyl phthalate
44.1,3-Dinitrobenzene
45.2,6-Dinitrotoluene
46.1,2-Dinitrobenzene
Peaks
47.Acenaphthylene
48.3-Nitroaniline
49.acenaphthene-d10 (IS)
50.Acenaphthene
51.2,4-Dinitrophenol
52.4-Nitrophenol
53.Dibenzofuran
54.2,4-Dinitrotoluene
55.2,3,5,6-Tetrachloro phenol
56.2,3,4,6-Tetrachlorophenol
57.Diethyl phthalate
58.Fluorene
59.4-Chlorophenyl phenyl ether
60.4-Nitroanaline
61.4,6-Dinitro-2-methylphenol
62.n-Nitroso-diphenylamine (diphenylamine
63.1,2-Diphenylhydrazine (as azobenzene)
64.2,4,6-Tribromophenol (SS)
65.4-Bromophenyl phenyl ether
66.Hexachlorobenzene
67.Pentachlorophenol
68.Phenanthrene-d10 (IS)
69.Phenanthrene
70.Anthracene
71.Carbazole
72.di-n-Butyl phthalate
73.Fluoranthene
74.Benzidine
75.Pyrene-d10 (SS)
76.Pyrene
77.p-terphenyl-d14 (SS)
78.3,3'-Dimethylbenzidine
79.Butyl benzyl phthalate
80.Bis(2-ethylhexyl) adipate
81.Benzo[a]anthracene
82.3,3'-Dichlorobenzidine
83.Chrysene-d12 (IS)
84.Chrysene
85.Bis(2-ethylhexyl)phthalate
86.Di-n-octyl phthalate
87.Benzo[b]fluoranthene
88.Benzo[k]fluoranthene
89.Benz[a]pyrene
90.Perylene-d12 (IS)
91.Indeno[1,2,3-cd]pyrene
92.Dibenzo[a,h]anthracene
93.Benzo[ghi]perylene
image
GC_EV00945
ColumnRxi-5Sil MS, 20 m, 0.18 mm ID, 0.18 µm (cat.# 43602)
Sample8270 MegaMix (cat.# 31850)
benzoic acid (cat.# 31879)
8270 Benzidines Mix (cat.# 31852)
Acid Surrogate Mix (4/89 SOW) (cat.# 31025)
Revised B/N Surrogate Mix (cat.# 31887)
1,4-dioxane (cat.# 31853)
SV Internal Standard Mix (cat.# 31206)
Conc.:10 ng/mL on-column concentration
Injection
Inj. Vol.:1.0 µL pulsed splitless (hold 0.15 min)
Liner:Drilled Uniliner (hole near bottom) (cat.# 20756)
Inj. Temp.:250 °C
Pulse Pressure:30 psi (206.8kPa)
Pulse Time:0.2 min
Purge Flow:60 mL/min
Oven
Oven Temp.:50 °C (hold 0.5 min) to 260 °C at 20 °C/min to 280 °C at 5 °C/min to 330 °C at 20 °C/min (hold 1.0 min)
Carrier GasHe, constant flow
Flow Rate:1.0 mL/min
DetectorMS
Mode:Scan
Transfer Line Temp.:280 °C
Ionization Mode:EI
Scan Range:35-550 amu
Download PDF

RELATED CHROMATOGRAM LIBRARY SEARCHES

semivolatile

,

Rxi-5SilMS

,

SVOC

Printing tips! To print chromatograms full page, change the print settings in the print dialogue window of your PDF reader software: 1) "fit" or "fit to page", 2) "landscape" for wide chromatograms or "portrait" for tall chromatograms.


Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us