share:

This chromatogram may contain analytes that are synonyms of your search terms.

QuEChERS Extract of NIST SRM 2974a Freeze-Dried Mussel Tissue (GCxGC contour plot)

Peaks
1.Naphthalene
2.2-Methylnaphthalene
3.1-Methylnaphthalene
4.Biphenyl
5.2,6-Dimethylnaphthalene
6.Acenaphthylene
7.Acenaphthene
8.2,3,5-Trimethylnaphthalene
9.Fluorene
10.Phenanthrene
11.Anthracene
12.1-Methylphenanthrene
Peaks
13.Fluoranthene
14.Pyrene
15.Benzo(a)anthracene
16.Chrysene
17.Benzo(b)fluoranthene
18.Benzo(k)fluoranthene
19.Benzo(j)fluoranthene
20.Benzo(e)pyrene
21.Benzo(a)pyrene
22.Perylene
23.Dibenz(a,h)anthracene
24.Indeno(1,2,3-cd)pyrene
25.Benzo(ghi)perylene
image
GC_FF1197
ColumnRxi-17Sil MS 30 m, 0.25 mm ID, 0.25 µm (cat.# 14123)
Rxi-1ms 1.2 m, 0.15 mm ID, 0.15 µm (cat.# custom)
SampleNIST SRM 2974a freeze-dried mussel tissue with incurred residues
Diluent:Acetonitrile
Injection
Inj. Vol.:1 µL splitless (hold 1 min)
Liner:Splitless taper (4 mm) w/semivolatiles wool (cat.# 20798-231.1)
Inj. Temp.:250 °C
Purge Flow:40 mL/min
Oven
Oven Temp.:Rxi-17Sil MS: 90 °C (hold 1 min) to 320 °C at 3.75 °C/min (hold 2.67 min)
Rxi-1ms: 95 °C (hold 1 min) to 325 °C at 3.75 °C/min (hold 2.67 min)
Carrier GasHe, corrected constant flow (2.2 mL/min)
Modulation
Modulator Temp. Offset:20 °C
Second Dimension Separation Time:3 sec
Hot Pulse Time:0.9 sec
Cool Time between Stages:0.6 sec
DetectorTOFMS
Transfer Line Temp.:300 °C
Analyzer Type:TOF
Source Temp.:250 °C
Electron Energy:70 eV
Mass Defect:-20 mu/100 u
Solvent Delay Time:5 min
Tune Type:PFTBA
Ionization Mode:EI
Acquisition Range:45 to 550 amu
Spectral Acquisition Rate:100 spectra/sec
InstrumentLECO Pegasus 4D GCxGC-TOFMS
NotesPAHs (shown in box) elute in a relatively narrow band and are identified by the white peak marker dots.
Download PDF

RELATED CHROMATOGRAM LIBRARY SEARCHES

Seafood

,

Gulf oil spill

,

PAHs

,

QuEChERS

,

SVOA

,

polycyclic aromatic hydrocarbons

,

polynuclear aromatic hydrocarbons

Printing tips! To print chromatograms full page, change the print settings in the print dialogue window of your PDF reader software: 1) "fit" or "fit to page", 2) "landscape" for wide chromatograms or "portrait" for tall chromatograms.


Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us