share:

This chromatogram may contain analytes that are synonyms of your search terms.

OVIs by Dynamic Headspace and Gerstel MACH on Rtx-WAX (G16)

PeaksConc.
(µg added)
1.Methanol6.00
2.Acetonitrile0.82
3.Dichloromethane1.20
4.trans-1,2-Dichloroethylene1.88
5.Hexane0.58
6.cis-1,2-Dichloroethylene1.88
7.Nitromethane0.10
8.Tetrahydrofuran1.38
9.Chloroform0.12
10.Cyclohexane7.76
11.1,2-Dimethoxyethane0.20
PeaksConc.
(µg added)
12.Trichloroethylene0.16
13.Methylcyclohexane2.36
14.1,4-Dioxane0.76
15.Pyridine0.40
16.Toluene1.78
17.2-Hexanone0.10
18.Chlorobenzene0.72
19.Ethyl benzene0.74
20.m-Xylene2.60
21.p-Xylene0.61
22.o-Xylene0.39
23.Tetralin0.20
* septum components
image
GC_PH00846
ColumnsRtx-WAX (G16) 20 m, 0.18 mm ID, 0.4 µm,
using IP Deactivated Guard Column 5 m, 0.32 mm ID (cat.# 10044)
with Universal “Y” Press-Tight Connector (cat.# 20405)
SampleResidual Solvents Class 2 - Mix A (cat.# 36271)
Residual Solvents Class 2 - Mix B (cat.# 36272)
Diluent:0.5mL DI water/~0.2g sodium sulfate in 20mL headspace vial
Injectionheadspace-trap split (split ratio 20:1)
Headspace-Trap
Instrument:Tekmar HT3
Inj. Temp.:220 °C
Transfer Line Temp.:220 °C
Valve Oven Temp.:220 °C
Oven Temp.:250 °C
Standby flow rate:50 mL/min
Trap Standby Temp:40 °C
Trap Sweep Temp:40 °C
Preheat Mixer:On
Preheat Mixer Time:2.00 min
Preheat Mixing Level:5
Preheat Mixer Stabilize Time:0.50 min
Sample Temp.:80 °C
Sample Equil. Time:15.00 min
Sweep Flow Rate:75 mL/min
Sweep Flow Time:5.00 min
Dry Purge: 10.00 min, flow 100 mL/min @ 25 °C
Desorb Preheat Temp:245 °C
Desorb: 1.00 min @ 250 °C
Trap Bake Temp:260 °C
Trap Bake Time:6.00 min
Trap Bake Flow:450 mL/min
Oven
Oven Temp.:250 °C
Carrier GasHe, constant flow
Flow Rate:0.99 mL/min
DetectorFID @ 250 °C
Make-up Gas Flow Rate:45 mL/min
InstrumentAgilent/HP6890 GC
NotesGerstel Modular Accelerated Column Heater (MACH): 35°C (2 min.) to 60°C at 100°C/min. (hold 1 min.), to 200°C at 40°C/min. (hold 2 min.)
Download PDF

Printing tips! To print chromatograms full page, change the print settings in the print dialogue window of your PDF reader software: 1) "fit" or "fit to page", 2) "landscape" for wide chromatograms or "portrait" for tall chromatograms.


Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us