share:

California Cannabis Pesticides and Mycotoxins in Brownies on Raptor ARC-18

PeakstR (min)Precursor IonProduct Ion 1Product Ion 2Polarity
1.Daminozide-d60.6167.0149.349.3+
2.Daminozide0.7161.144.1143.2+
3.Acephate1.5184.0143.195.1+
4.Oxamyl1.8237.172.190.1+
5.Flonicamid1.9230.1203.1174.1+
6.Methomyl1.9163.188.1106.1+
7.Thiamethoxam1.9292.0211.1181.1+
8.Imidacloprid2.2256.1209.1175.1+
9.Mevinphos I2.2225.1127.1193.2+
10.Acetamiprid2.2223.0126.156.1+
11.Dimethoathe-d62.2236.1205.1-+
12.Dimethoate2.3230.0199.1125.1+
13.Thiacloprid2.4253.0126.090.1+
14.Mevinphos II2.4225.1127.1193.2+
15.Aflatoxin G22.4331.2189.3115.2+
16.Aflatoxin G12.4329.2243.2215.3+
17.Aldicarb2.5116.089.270.2+
18.Aflatoxin B22.5315.3287.2243.3+
19.Dichlorvos2.6220.9109.179.2+
20.Dichlorvos-d62.6227.0115.1-+
21.Aflatoxin B12.6313.2241.2128.2+
22.Imazalil2.6297.0159.0201.0+
23.Carbofuran2.6222.1123.1165.2+
24.Propoxur2.6210.1111.193.1+
25.Carbaryl-d72.7209.2152.2-+
26.Carbaryl2.7202.1145.1127.1+
27.Diuron-d62.9239.178.2-+
28.Atrazine-d52.9221.2179.1-+
29.Naled2.9397.8127.1109.1+
30.Metalaxyl2.9280.2220.2192.2+
31.Spiroxamine2.9298.3144.2100.2+
32.Chlorantraniliprole3.0483.9452.9285.9+
33.Phosmet3.0318.0160.177.2+
34.Azoxystrobin3.1404.0372.1344.1+
35.Linuron-d63.1255.1160.1-+
36.Fludioxonil3.2247.0180.0126.0-
37.Methiocarb3.2226.1169.1121.1+
38.Dimethomorph I3.2388.2301.2165.3+
39.Boscalid3.2342.9307.1140.1+
40.Paclobutrazol3.3294.370.1125.1+
41.Malathion3.3331.0127.2285.2+
42.Dimethomorph II3.4388.2301.2165.3+
43.Myclobutanil3.4289.170.1125.1+
44.Bifenazate3.4301.0198.1170.2+
45.Ochratoxin A3.5404.2239.1358.3+
46.Fenhexamid3.5302.197.155.2+
47.Spirotetramat3.7374.2302.1216.1+
48.Ethoprophos3.8243.1131.197.1+
49.Fipronil3.8436.8331.8251.9-
50.Fenoxycarb3.9302.188.1116.1+
51.Kresoxim-methyl4.1314.2267.2222.2+
52.Tebuconazole4.2308.170.1125.1+
53.Diazinon-d10 4.2315.2170.2-+
54.Spinosyn A (spinosad)4.3732.4142.298.1+
55.Diazinon4.3305.1169.2153.2+
56.Coumaphos4.4363.1227.1307.1+
57.Pyridaben4.4365.1309.2147.2+
58.Propiconazole4.4342.0159.069.2+
59.Clofentezine4.5303.0138.1102.1+
60.Spinosyn D (spinosad)4.8746.5142.398.4+
61.Spinosyn J (spinetoram)4.8748.5142.398.3+
62.Trifloxystrobin4.9409.2186.1145.1+
63.Prallethrin4.9301.2123.2105.2+
64.Pyrethrin II5.2373.1161.1133.2+
65.Spinosyn L (spinetoram)5.4760.5142.298.1+
66.Piperonyl butoxide5.7356.3177.2119.2+
67.Chlorpyrifos5.8349.9198.097.1+
68.Hexythiazox5.9353.1228.1168.1+
69.Etoxazole6.4360.2141.1304.2+
70.Spiromesifen6.4273.2255.2187.2+
71.Pyrethrin I6.6329.2161.2105.2+
72.Cyfluthrin (qualifier)6.6453.1193.2-+
73.Cyfluthrin6.6451.1191.2-+
74.Cypermethrin6.8433.1191.0416.0+
75.Fenpyroximate6.8422.2366.1138.1+
76.trans-Permethrin7.4408.3183.2355.1+
77.cis-Permethrin7.7408.3183.2355.1+
78.Avermectin B1a7.7890.5305.4567.4+
79.Etofenprox7.8394.3177.2359.3+
80.Bifenthrin8.0440.0181.2166.2+
81.Acequinocyl (precursor ion 1)9.3402.3343.2189.0+
82.Acequinocyl (precursor ion 2)9.3386.0344.2189.1+
image
LC_GN0602
ColumnRaptor ARC-18 (cat.# 9314A12)
Dimensions:100 mm x 2.1 mm ID
Particle Size:2.7 µm
Pore Size:90 Å
Guard Column:Raptor ARC-18 EXP guard column cartridge 5 mm, 2.1 mm ID, 2.7 µm (cat.# 9314A0252)
Temp.:40 °C
SampleCalifornia pesticide standard #1 (cat.# 34124)
California pesticide standard #2 (cat.# 34125)
California pesticide standard #3 (cat.# 34126)
California pesticide standard #4 (cat.# 34127)
California pesticide standard #5 (cat.# 34128)
California pesticide standard #6 (cat.# 34129)
Dimethoate-d6 (cat.# 31988)
Dichlorvos-d6 (cat.# 31987)
Carbaryl-d7 (cat.# 31985)
Diazinon-d10 (cat.# 31986)
Atrazine-d5 (cat.# 31984)
Diuron-d6 (cat.# 31989)
Liuron-d6 (cat.# 31990)
Diluent:75:25 Acetonitrile:water
Conc.:5-15 ng/mL (Expected concentration range in extract of brownie initially spiked at 100 ng/g.)
Inj. Vol.:2 µL
Mobile Phase
A:Water, 2 mM ammonium formate, 0.1% formic acid
B:Methanol, 2 mM ammonium formate, 0.1% formic acid
Time (min)Flow (mL/min)%A%B
0.000.5955
1.50.53565
8.50.5595
9.50.50100
10.50.50100
10.60.5955
120.5955
DetectorMS/MS
Ion Mode:ESI+/ESI-
Mode:MRM
InstrumentUHPLC
NotesBrownies were pulverized using a SPEX Freezer/Mill grinder and 0.5 g samples were fortified with pesticides and mycotoxins at 100 ng/g. A mix of internal standards was added at 200 ng/g. 1.5 mL of acetonitrile acidified with 1% acetic acid was added to the sample. The sample was vortexed and sonicated for 5 min, and then the supernatant was passed through a 100 mg Resprep C18 SPE cartridge (cat.# 26030). An additional 1.5 mL of extraction solvent (acidified acetonitrile) was added to the sample pellet, and then the sample was vortexed again. The supernatant was passed through the same C18 cartridge. 750 µL of extract was mixed with 250 µL of water, and then centrifuged for 5 min at low temperature (~7 ⁰C). 2 μL of final extract was injected into the LC-MS/MS system.


Download PDF

RELATED CHROMATOGRAM LIBRARY SEARCHES

Mycotoxins

,

California

,

Pesticides

,

,

Cannabis

Printing tips! To print chromatograms full page, change the print settings in the print dialogue window of your PDF reader software: 1) "fit" or "fit to page", 2) "landscape" for wide chromatograms or "portrait" for tall chromatograms.


Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us