California Cannabis Pesticides and Mycotoxins in Gummy Edibles on Raptor ARC-18
Peaks
tR (min)
Precursor Ion
Product Ion 1
Product Ion 2
Polarity
1.
Daminozide-d6
0.7
167.0
149.3
49.3
+
2.
Daminozide
0.7
161.1
44.1
143.2
+
3.
Acephate
1.7
184.0
143.1
95.1
+
4.
Oxamyl
2.0
237.1
72.1
90.1
+
5.
Flonicamid
2.1
230.1
203.1
174.1
+
6.
Methomyl
2.1
163.1
88.1
106.1
+
7.
Thiamethoxam
2.1
292.0
211.1
181.1
+
8.
Imidacloprid
2.3
256.1
209.1
175.1
+
9.
Mevinphos
2.4
225.1
127.1
193.2
+
10.
Acetamiprid
2.4
223.0
126.1
56.1
+
11.
Dimethoathe-d6
2.4
236.1
205.1
-
+
12.
Dimethoate
2.4
230.0
199.1
125.1
+
13.
Thiacloprid
2.5
253.0
126.0
90.1
+
14.
Aflatoxin G2
2.5
331.2
189.3
115.2
+
15.
Aflatoxin G1
2.5
329.2
243.2
215.3
+
16.
Aldicarb
2.6
116.0
89.2
70.2
+
17.
Aflatoxin B2
2.6
315.3
287.2
243.3
+
18.
Dichlorvos
2.7
220.9
109.1
79.2
+
19.
Dichlorvos-d6
2.7
227.0
115.1
-
+
20.
Aflatoxin B1
2.7
313.2
241.2
128.2
+
21.
Imazalil
2.7
297.0
159.0
201.0
+
22.
Carbofuran
2.7
222.1
123.1
165.2
+
23.
Propoxur
2.7
210.1
111.1
93.1
+
24.
Carbaryl-d7
2.8
209.2
152.2
-
+
25.
Carbaryl
2.8
202.1
145.1
127.1
+
26.
Diuron-d6
3.0
239.1
78.2
-
+
27.
Atrazine-d5
3.0
221.2
179.1
-
+
28.
Naled
3.1
397.8
127.1
109.1
+
29.
Metalaxyl
3.1
280.2
220.2
192.2
+
30.
Spiroxamine
3.1
298.3
144.2
100.2
+
31.
Chlorantraniliprole
3.2
483.9
452.9
285.9
+
32.
Phosmet
3.2
318.0
160.1
77.2
+
33.
Azoxystrobin
3.3
404.0
372.1
344.1
+
34.
Linuron-d6
3.3
255.1
160.1
-
+
35.
Fludioxonil
3.4
247.0
180.0
126.0
-
36.
Methiocarb
3.4
226.1
169.1
121.1
+
37.
Dimethomorph
3.5
388.2
301.2
165.3
+
38.
Boscalid
3.5
342.9
307.1
140.1
+
39.
Paclobutrazol
3.6
294.3
70.1
125.1
+
40.
Malathion
3.6
331.0
127.2
285.2
+
41.
Myclobutanil
3.7
289.1
70.1
125.1
+
42.
Bifenazate
3.7
301.0
198.1
170.2
+
43.
Ochratoxin A
3.8
404.2
239.1
358.3
+
44.
Fenhexamid
3.9
302.1
97.1
55.2
+
45.
Spirotetramat
4.0
374.2
302.1
216.1
+
46.
Ethoprophos
4.1
243.1
131.1
97.1
+
47.
Fipronil
4.1
436.8
331.8
251.9
-
48.
Fenoxycarb
4.2
302.1
88.1
116.1
+
49.
Kresoxim-methyl
4.4
314.2
267.2
222.2
+
50.
Tebuconazole
4.4
308.1
70.1
125.1
+
51.
Diazinon-d10
4.6
315.2
170.2
-
+
52.
Spinosyn A (Spinosad)
4.6
732.4
142.2
98.1
+
53.
Diazinon
4.6
305.1
169.2
153.2
+
54.
Coumaphos
4.7
363.1
227.1
307.1
+
55.
Pyridaben
4.7
365.1
309.2
147.2
+
56.
Propiconazole
4.7
342.0
159.0
69.2
+
57.
Clofentezine
4.8
303.0
138.1
102.1
+
58.
Spinosyn D (Spinosad)
5.0
746.5
142.3
98.4
+
59.
Spinosyn J (Spinetoram)
5.1
748.5
142.3
98.3
+
60.
Trifloxystrobin
5.3
409.2
186.1
145.1
+
61.
Prallethrin
5.3
301.2
123.2
105.2
+
62.
Pyrethrin II
5.5
373.1
161.1
133.2
+
63.
Spinosyn L (Spinetoram)
5.6
760.5
142.2
98.1
+
64.
Piperonyl butoxide
6.0
356.3
177.2
119.2
+
65.
Chlorpyrifos
6.1
349.9
198.0
97.1
+
66.
Hexythiazox
6.2
353.1
228.1
168.1
+
67.
Etoxazole
6.6
360.2
141.1
304.2
+
68.
Spiromesifen
6.7
273.2
255.2
187.2
+
69.
Pyrethrin I
6.9
329.2
161.2
105.2
+
70.
Cyfluthrin (qualifier)
6.9
453.1
193.2
-
+
71.
Cyfluthrin
6.9
451.1
191.2
-
+
72.
Cypermethrin
7.1
433.1
191.0
416.0
+
73.
Fenpyroximate
7.1
422.2
366.1
138.1
+
74.
trans-Permethrin
7.6
408.3
183.2
355.1
+
75.
cis-Permethrin
7.9
408.3
183.2
355.1
+
76.
Avermectin B1a
7.9
890.5
305.4
567.4
+
77.
Etofenprox
8.0
394.3
177.2
359.3
+
78.
Bifenthrin
8.2
440.0
181.2
166.2
+
79.
Acequinocyl (precursor ion 1)
9.4
402.3
343.2
189.0
+
80.
Acequinocyl (precursor ion 2)
9.4
386.0
344.2
189.1
+
LC_GN0666
Column
Raptor ARC-18 (cat.# 9314A12)
Dimensions:
100 mm x 2.1 mm ID
Particle Size:
2.7 µm
Pore Size:
90 Å
Guard Column:
Raptor ARC-18 EXP guard column cartridge 5 mm, 2.1 mm ID, 2.7 µm (cat.# 9314A0252)
Temp.:
40 °C
Sample
California pesticide standard #1 (cat.# 34124)
California pesticide standard #2 (cat.# 34125)
California pesticide standard #3 (cat.# 34126)
California pesticide standard #4 (cat.# 34127)
California pesticide standard #5 (cat.# 34128)
California pesticide standard #6 (cat.# 34129)
Dimethoate-d6 (cat.# 31988)
Dichlorvos-d6 (cat.# 31987)
Carbaryl-d7 (cat.# 31985)
Diazinon-d10 (cat.# 31986)
Atrazine-d5 (cat.# 31984)
Diuron-d6 (cat.# 31989)
Liuron-d6 (cat.# 31990)
Aflatoxins standard (cat.# 34121)
Ochratoxin A (cat.# 34122)
Compounds not present in these mixes were obtained separately.
Diluent:
75:25 Acetonitrile:water
Conc.:
3.75-15 ng/mL (Expected concentration range in extract of gummy initially spiked at 100 ng/g.)
Inj. Vol.:
2 µL
Mobile Phase
A:
Water, 2 mM ammonium formate, 0.1% formic acid
B:
Methanol, 2 mM ammonium formate, 0.1% formic acid
Time (min)
Flow (mL/min)
%A
%B
0.00
0.5
95
5
1.5
0.5
35
65
8.5
0.5
5
95
9.5
0.5
0
100
10.5
0.5
0
100
10.6
0.5
95
5
12.0
0.5
95
5
Detector
MS/MS
Ion Mode:
ESI+/ESI-
Mode:
MRM
Instrument
UHPLC
Notes
Gummies were manually chopped into small pieces, and 1 g of sample was weighed in a 50 mL polypropylene tube. The sample was mixed with 5 mL of water and then vigorously vortexed until all gummy pieces were fully solubilized. The sample was fortified with pesticides and mycotoxins at 100 ng/g. A mix of internal standards was added at 200 ng/g. The spiked sample was further vortexed for 30 sec. 5 mL of acetonitrile acidified with 1% acetic acid was added to the sample, and this was followed by a 30 sec vortex agitation. Then, a pouch of European EN 15662 QuEChERS extraction salts (cat.# 25849) was added to the sample. The sample was vortexed for 30 sec and then centrifuged for 5 min. 750 µL of organic extract was mixed with 250 µL of water. 2 μL of final extract was injected into the LC-MS/MS system.
Printing tips! To print chromatograms full page, change the print settings in the print dialogue window of your PDF reader software: 1) "fit" or "fit to page", 2) "landscape" for wide chromatograms or "portrait" for tall chromatograms.
Recommendations
Restek Domestic Customer Service
Thank you
Your message has been sent. We will be in touch shortly.
Message not sent
Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.
Cookies allow for a variety of features that make your visit to Restek more enjoyable. By using this website, you agree to the use of cookies in accordance with our guidelines. For more information, see our privacy policy.