Rt-Alumina BOND/KCl Columns (fused silica PLOT)

KCl deactivation

... retention indices for propadiene and methyl acetylene. The resolution of trans-2-butene and 1-butene is also ... -butane. Methyl acetylene (impurity in 1,3-butadiene) elutes before 1,3-butadiene the need for frequent regeneration. Acetylene elutes before n...

MXT-Alumina BOND/MAPD Columns (Siltek-treated stainless steel PLOT)

.../MAPD column for improved analysis of trace concentrations of polar hydrocarbons like acetylene, methyl acetylene, and propadiene in hydrocarbon streams containing higher levels of C1-C5 hydrocarbons. Our new ... of acetylene, methyl acetylene, and propadiene. Stable response factors make this column ideal...

Rt-Alumina BOND/MAPD Columns (fused silica PLOT)

... retention indices for propadiene and methyl acetylene. The resolution of trans-2-butene and 1-butene is also analysis of trace concentrations of polar hydrocarbons like acetylene, methyl acetylene, and propadiene ... of acetylene, methyl acetylene, and propadiene. Stable response factors make this column ideal...

Rt-Alumina BOND/Na2SO4 Columns (fused silica PLOT)

Na2SO4 deactivation

..., while selectivity is measured using retention indices for propadiene and methyl acetylene ... isomers (impurities in butene streams). Methyl acetylene elutes after 1,3-butadiene Acetylene and propadiene elute after butanes. Best separation for butene...

Rt-Alumina BOND/CFC Columns (fused silica PLOT)

... retention indices for propadiene and methyl acetylene. The resolution of trans-2-butene and 1-butene is also...

Improve Trace Analysis of Acetylene, Propadiene, and Methyl Acetylene Impurities with Higher Capacity Alumina MAPD Columns (PDF 351kB)

... Analysis of Acetylene, Propadiene, and Methyl Acetylene Impurities with Higher Capacity Alumina MAPD of impurities, such as acetylene, propadiene, or methyl acetylene, must be detected in order to prevent damage...

Analyze Trace Polar Hydrocarbons More Accurately and Reliably With New Alumina BOND/MAPD PLOT Columns! (PDF 2703kB)

... analysis of polar hydrocarbons like propadiene, acetylene, and methyl acetylene. Successful analysis as MAPD columns (for methyl acetylene and propadiene), have been developed specifically...

Analysis of Trace Hydrocarbon Impurities in 1,3-Butadiene Using Optimized Rt-Alumina BOND/MAPD PLOT Columns (PDF 408kB)

... both common light polar contaminants, including methyl acetylene and propadiene, as well as 4 purification, it is also important that 1,3-butadiene be free of propadiene and methyl acetylene, which can ... butadiene, MAPD column, 4-vinylcyclohexene, alumina PLOT column, synthetic rubber, methyl acetylene...

How to Understand and Deal with Overloading in GC (PDF 241kB)

..., methyl-acetylene and 1,3 butadiene, tail significantly. The overloaded hydrocarbons also elute earlier ). Dilutingofthesamplepriortoinjection. Figure 5: Impact of temperature on peak shape of 1,3-butadiene and methyl acetylene. Column: 30...

Analysis of Impurities in Ethylene by ASTM D6159-97 (PDF 1789kB)

..., and there is a complete coelution between methyl acetylene and n-pentane (peaks 16 and 17). Figure 2 Analyzing ethylene . methyl acetylene 17. n-pentane 18. 1,3-butadiene GCPC01138 Column: Sample: Inj.: Rt -Alumina BOND...

Improve Trace Analysis of Acetylene, Propadiene, and Methyl Acetylene Impurities With Higher Sample Capacity Alumina MAPD Columns

... trace levels of impurities, such as acetylene, propadiene, or methyl acetylene, must be detected impurities, such as acetylene, propadiene, and methyl acetylene in petroleum gases, the sample handling ... for analyzing acetylene, propadiene, and methyl acetylene in petroleum gases. Greater capacity improves data...

Analysis of Trace Hydrocarbon Impurities in 1,3-Butadiene Using Optimized Rt-Alumina BOND/MAPD PLOT Columns

... used to separate both common light polar contaminants, including methyl acetylene and propadiene be free of propadiene and methyl acetylene, which can interfere with catalytic polymerization. Alumina ... of both light polar impurities (methyl acetylene, propadiene) and 4-vinylcyclohexene, a heavier ... MAPD column, 4-vinylcyclohexene, alumina PLOT column, synthetic rubber, methyl acetylene...

News: Improve Trace Analysis of Acetylene, Propadiene, and Methyl Acetylene Impurities With Higher Capacity Alumina MAPD Columns

Author(s): Rick Morehead, Jan Pijpelink, Jaap de Zeeuw Published By: Petro Industry News Year of Publication: 2011 Link: http://www.restek.com/Technical-Resources/Technical-Library/Petroleum-Petrochemical/petro_PCAN1537-UNV Abstract: When analysing trace impurities in petroleum gases, such as propylene, ethylene, or 1,3-butadiene, column capacity (loadability) is an important factor in obtaining accurate … Continue reading

Restek's PLOT Column Family (PDF 3255kB)

... for propadiene and methyl acetylene. The resolution of trans-2-butene and 1-butene is also verified and isomers (impurities in butene streams). • Methyl acetylene elutes after 1,3-butadiene. • Cyclopropane...

17 Minute D2712 Analysis of Impurities in Propylene Using PLOT Columns (PDF 1608kB)

...-butene 15. isopentane 16. n-pentane 17. 1,3-butadiene 18. methyl acetylene Excellent peak shape . n-butane 9. propadiene 10. acetylene 11. trans-2-butene 12. 1-butene 13. isobutylene 14. cis-2...

New PLOT Column Technology Stabilises Flow and Improves Analysis of Light Hydrocarbons, Solvents and Permanent Gases (PDF 1947kB)

... a relatively nonpolar surface. The polar hydrocarbons acetylene, methyl acetylene, and propadiene are strongly separation of propadiene and acetylene from n-butane is also observed and can be further increased...

Solutions for Your Petro Analyses (PDF 7050kB)

.... Propadiene 9. n-Butane 10. 1-Butene 11. Methyl acetylene 12. 1,3-Butadiene 13. trans-2-Butene 14 -butane. • Methyl acetylene (impurity in 1,3-butadiene) elutes before 1,3-butadiene. • Acetylene and propadiene...

News: Analysis of Trace Hydrocarbon Impurities in 1,3-Butadiene Using Optimized Rt®-Alumina BOND/MAPD PLOT Columns

Author(s): Rick Morehead, Jan Pijpelink, Jaap de Zeeuw, Tom Vezza Published By: Restek Corporation Year of Publication: 2011 Link: http://www.restek.com/Technical-Resources/Technical-Library/Petroleum-Petrochemical/petro_PCAN1434 Abstract: Impurity analysis of 1,3-butadiene on an Rt®-Alumina BOND/MAPD column results in good separation of both light polar impurities (methyl acetylene, … Continue reading

ChromaBLOGraphy: Speed up Separations and Maximize acetylene, propadiene and methylacetylene Response using High flow and Short alumina MAPD columns

Last week I had the chance to do some labwork at Restek on light hydrocarbon analysis looking at fast analysis of trace polar hydrocarbons (acetylene, propadiene). For this application, a new column was developed : AluminaBOND / MAPD.  See also:  http://blog.restek.com/?p=2670   I always was amazed by the selectivity of the alumina adsorbent for hydrocarbon [...]

ChromaBLOGraphy: New Alumina PLOT provides Highest Acetylene/Propadiene Response and extended Maximum Temperature

During last ISCC symposium in San Diego, several posters were presented on alumina PLOT technology and application. One poster was about a new alumina columns with improved characteristics. The other poster was about separation behavior of alumina. Here we zoom into the new Alumina technology. In light hydrocarbon analysis, the separation and detection of traces [...]

Restek's PLOT Column Family PCSS1163G-UNV

Restek's porous layer open tubular (PLOT) columns feature an innovative bonding process that minimizes particle release, more consistent flow for stable retention times, and outstanding peak symmetry to improve impurity analysis. Restek PLOT columns are the benchmark for performance.

ChromaBLOGraphy: [24] What do Chromatograms tell us? Base line is Rising with a Near Constant Slope..

Chromatograms are like fingerprints.  If you can “read” chromatograms well, you often can find a plausible cause. In this series, we will show a series of GC-chromatograms that are obtained from users and discuss some potential causes for the phenomena. Then we can move into some solutions for improvement.   In chromatography, we always like […]

ChromaBLOGraphy: Limitations of Alumina: What you should NOT inject on alumina / Al2O3 columns

Alumina (Al2O3) capillary PLOT columns have been available for about 35 years. They are best suited for separation of C1-C10 hydrocarbons and especially the C1-C5 range. The alumina has unique selectivity making it possible to separate all the unsaturated hydrocarbons at temperatures above ambient, see figure 1. While its an excellent choice for unsaturated hydrocarbons, special attention is […]

For advanced chromatogram searching, please check out our Chromatogram Library Search Tool.

C1-C5 Hydrocarbons on Rt-Alumina BOND/MAPD

GC_PC1213

Column: Rt-Alumina BOND/MAPD, 50 m, 0.53 mm ID, 10 µm (cat.# 19778)
Injector: Split
Detector: FID

1,3-Butadiene on Rt-Alumina BOND/MAPD (Purity Analysis)

GC_PC1211

Column: Rt-Alumina BOND/MAPD, 50 m, 0.53 mm ID, 10.0 µm (cat.# 19778)
Injector: Split
Detector: FID

Crude 1,3-Butadiene on Rt-Alumina BOND/MAPD

GC_PC1202

Column: Rt-Alumina BOND/MAPD, 50 m, 0.53 mm ID, 10 µm (cat.# 19778)
Injector: Split
Detector: FID

Propylene and C1-C5 Hydrocarbons on Rt-Alumina BOND/Na2SO4

GC_PC01142

Column: Rt-Alumina BOND/Na2SO4, 50 m, 0.53 mm ID, 10 µm (cat.# 19756)
Injector: Split
Detector: FID

Refinery Gas Mix on Rt-QS-BOND

GC_PC01054

Column: Rt-QS-BOND, 30 m, 0.53 mm ID, 20 µm (cat.# 19738)
Injector: Split
Detector: FID

Ethylene and C1-C5 Hydrocarbons by ASTM D6159-97 on Rt-Alumina BOND/KCl, Rtx-1

GC_PC01110

Column: Rt-Alumina BOND/KCl *, 50 m, 0.53 mm ID, 10 µm (cat.# 19760)
Injector: Split
Detector: FID

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us