15 result(s)
Alicat M-Series Flow Calibrators
....8% of the reading + 0.2% full-scale repeatability; calibration documents provided with each unit. Fast at Calibration Conditions After Tare: ± 0.8% of reading + 0.2% of full scale...
GC Accelerator Oven Insert Kit
for Agilent 6890 and 7890 instruments
... samples. When faster ramp rates are used, existing methods can be accurately scaled down to smaller, high -efficiency, narrow-bore columns using Restek’s EZGC method translator. With a scaled ... See our scaled-down translated methods for faster ... GC method translator to accurately convert methods to a scaled-down column format. Scaled...
Ultra Silica HPLC Prep Columns
... Easy scale-up from Restek analytical columns. Popular bonded phases . Restek makes it easy to scale up your separations. We offer a wide range of semipreparative ... separation on an equivalent analytical-scale column. Because we cannot reuse a column or the silica it contains once it has left our facility, we cannot accept returns of large-scale columns....
Ultra C18 HPLC Prep Columns
... Easy scale-up from Restek analytical columns. Popular bonded phases . Restek makes it easy to scale up your separations. We offer a wide range of semipreparative ... separation on an equivalent analytical-scale column. Because we cannot reuse a column or the silica it contains once it has left our facility, we cannot accept returns of large-scale columns....
Ultra C8 HPLC Prep Columns
... Easy scale-up from Restek analytical columns. Popular bonded phases . Restek makes it easy to scale up your separations. We offer a wide range of semipreparative ... separation on an equivalent analytical-scale column. Because we cannot reuse a column or the silica it contains once it has left our facility, we cannot accept returns of large-scale columns....
Ultra Cyano HPLC Prep Columns
... Easy scale-up from Restek analytical columns. Popular bonded phases . Restek makes it easy to scale up your separations. We offer a wide range of semipreparative ... separation on an equivalent analytical-scale column. Because we cannot reuse a column or the silica it contains once it has left our facility, we cannot accept returns of large-scale columns....
Ultra IBD HPLC Prep Columns
... Easy scale-up from Restek analytical columns. Popular bonded phases . Restek makes it easy to scale up your separations. We offer a wide range of semipreparative ... separation on an equivalent analytical-scale column. Because we cannot reuse a column or the silica it contains once it has left our facility, we cannot accept returns of large-scale columns....
Ultra Biphenyl Prep Columns
... Easy scale-up from Restek analytical columns. Popular bonded phases . Restek makes it easy to scale up your separations. We offer a wide range of semipreparative ... separation on an equivalent analytical-scale column. Because we cannot reuse a column or the silica it contains once it has left our facility, we cannot accept returns of large-scale columns....
Ultra PFP Propyl Prep Columns
... Easy scale-up from Restek analytical columns. Popular bonded phases . Restek makes it easy to scale up your separations. We offer a wide range of semipreparative ... separation on an equivalent analytical-scale column. Because we cannot reuse a column or the silica it contains once it has left our facility, we cannot accept returns of large-scale columns....
Ultra Aqueous C18 HPLC Prep Columns
... Easy scale-up from Restek analytical columns. Popular bonded phases . Restek makes it easy to scale up your separations. We offer a wide range of semipreparative ... separation on an equivalent analytical-scale column. Because we cannot reuse a column or the silica it contains once it has left our facility, we cannot accept returns of large-scale columns....
Ultra Bulk Packing Materials (5 µm)
Use our bulk packing materials to pack your own columns!
....Use these materials for easy scale-up to preparative chromatography or for packing your own columns....
Faster Semivolatiles Analysis with a Scaled-Down Method and GC Accelerator Kit (PDF 1306kB)
... productivity. You can significantly speed up methods on your existing GC-MS by using a properly scaled . In this technical article, we will walk through an example of scaling down EPA Method 8270 and using a GC...
Column Choice: A Critical Factor for Successful UHPLC Integration
... be transferred to UHPLC (scale down). Alternatively, to lessen time in method development, a preliminary and ease method transfer while scaling an analysis, the properties of the silica used in the columns must ... Column choice is a critical factor in successfully transferring methods between UHPLC and HPLC ... scaling methods, accuracy, method transfer, HPLC, UHPLC...
Faster Semivolatiles Analysis with a Scaled-Down Method and GC Accelerator Kit
... productivity. You can significantly speed up methods on your existing GC-MS by using a properly scaled . In this technical article, we will walk through an example of scaling down EPA Method 8270 and using a GC ... to scale an existing method on a traditional format (30 m, 0.25 mm ID, 0.25 µm df) arylene-type column down to a 20 m long, 0.15 mm ID, 0.15 µm df column. By using a properly scaled column and method along...
Restek LC Columns and Accessories (PDF 17409kB)
... to 3 μm to 5 μm. Ideal for: Scaling methods between HPLC and UHPLC. Instruments supported: • Agilent information about Restek products, applications, instrument troubleshooting, method development, and more...