share:

Resprep Oil & Grease SPE Disks

... by previous EPA methods. No chlorofluorocarbons needed. ...

Rt-Alumina BOND/CFC Columns (fused silica PLOT)

... Improved inertness for chlorofluorocarbon (CFC) compounds. Highly selective...

New Alumina Column Shows Promise for Analysing Chlorofluorocarbons (PDF 2249kB)

... Promise for Analysing Chlorofluorocarbons Chlorofluorocarbons (CFCs) are a group of halogenated hydrocarbons, without the activity that is usually observed with alumina adsorbents.Chlorofluorocarbon...

New Alumina Column Shows Promise for Analyzing Chlorofluorocarbons

.... Chlorofluorocarbon analysis, in particular, can benefit from this new technology. Chlorofluorocarbons . Figure 5:  Separation of chlorofluorocarbons on an Rt-Alumina BOND/CFC column ... hydrocarbons, without the activity that is usually observed with alumina adsorbents. Chlorofluorocarbon ... CFC, chlorofluorocarbon, "halogenated hydrocarbon", alumina...

News: New Alumina Column Shows Promise for Analyzing Chlorofluorocarbons

Author(s): Jaap de Zeeuw, Tom Vezza Published By: Petro Industry News Year of Publication: 2011 Link: http://www.restek.com/Technical-Resources/Technical-Library/Petroleum-Petrochemical/petro_0020 Abstract: Rt®-Alumina BOND/CFC columns provide high retention and high selectivity for volatile halogenated hydrocarbons, without the activity that is usually observed with alumina adsorbents. … Continue reading

Restek's PLOT Column Family (PDF 3255kB)

... inertness for chlorofluorocarbon (CFC) compounds. • Highly selective alumina-based column, separates most...

Solutions for Your Petro Analyses (PDF 7050kB)

.... • Improved inertness for chlorofluorocarbon (CFC) compounds. • Highly selective alumina-based column...

1-Type Column

1-Type Column

ChromaBLOGraphy: Limitations of Alumina: What you should NOT inject on alumina / Al2O3 columns

Alumina (Al2O3) capillary PLOT columns have been available for about 35 years. They are best suited for separation of C1-C10 hydrocarbons and especially the C1-C5 range. The alumina has unique selectivity making it possible to separate all the unsaturated hydrocarbons at temperatures above ambient, see figure 1. While its an excellent choice for unsaturated hydrocarbons, special attention is […]

Restek's PLOT Column Family PCSS1163G-UNV

Restek's porous layer open tubular (PLOT) columns feature an innovative bonding process that minimizes particle release, more consistent flow for stable retention times, and outstanding peak symmetry to improve impurity analysis. Restek PLOT columns are the benchmark for performance.

For advanced chromatogram searching, please check out our Chromatogram Library Search Tool.

Chlorofluorocarbons Rtx-1

GC_CH00320

Column: Rtx-1, 105 m, 0.25 mm ID, 1.00 µm (cat.# 10159)
Injector: Split
Detector: MS-Scan

Chlorofluorocarbons on Rtx-1

GC_CH00319

Column: Rtx-1, 105 m, 0.25 mm ID, 1.00 µm (cat.# 10159)
Injector: Split
Detector: MS-Scan

Chlorofluorocarbons on Rtx-200

GC_CH00322

Column: Rtx-200, 105 m, 0.53 mm ID, 3.00 µm (cat.# 15091)
Injector: Splitless
Detector: MS-Scan

Chlorofluorocarbons on Rtx-1

GC_CH00321

Column: Rtx-1, 105 m, 0.53 mm ID, 3.00 µm (cat.# 10189)
Injector: Splitless
Detector: MS-Scan

Chlorofluorocarbons 5% Krytox on 60/80 CarboBlack B

GC_CH00323

Column: SilcoSmooth™ stainless steel tubing, 60/80 mesh on CarboBlack B, 3.05m, 1/8in. OD, 2.1 mm ID (cat.# Custom)
Injector: On-Column - Packed
Detector: FID

Freon 12 and Ethylene Oxide on Rtx-1

GC_CH00324

Column: Rtx-1, 30 m, 0.53 mm ID, 5.00 µm (cat.# 10179)
Injector: Split
Detector: FID

Freon 12 & Ethylene Oxide on Rtx-200

GC_CH00325

Column: Rtx-200, 30 m, 0.53 mm ID, 3.00 µm (cat.# 15085)
Injector: Direct
Detector: FID

Impurity Analysis of 1,1,1,2-Tetrafluoroethane (CFC-134a) on Rt-Alumina BOND/CFC

GC_GN1155

Column: Rt-Alumina BOND/CFC, 30 m, 0.53 mm ID (cat.# 19763)
Injector: Split
Detector: FID

Chlorofluorocarbon Gases on ShinCarbon ST (micropacked)

GC_PC00673

Column: SilcoSmooth® tubing, 100/120 mesh on ShinCarbon ST, 1 m-1, 1/16-1 OD, 1.0 mm ID (cat.# 19809)
Injector: On-Column - Packed
Detector: FID

Chlorofluorocarbons (CFCs) on Rt-Alumina BOND/CFC

GC_PC1199

Column: Rt-Alumina BOND/CFC, 30 m, 0.53 mm ID, 10 µm (cat.# 19763)
Injector: Split
Detector: FID

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us