Sulfur 5-Component Mix (5 components)

...Carbonyl sulfideDimethyl sulfideEthyl mercaptanHydrogen sulfideMethyl mercaptan...

Speciated Sulfur System Suitability Checkout Standard (SSSSCS)

... tertiary butyl mercaptan50.0 ppm total sulfur by weight from thiopene15.0 ppm total sulfur...

Rt-U-BOND Columns (fused silica PLOT)

divinylbenzene ethylene glycol/dimethylacrylate

... and nonpolar compounds. Common applications include: trace H2S, COS, and mercaptans...

Rt-XLSulfur Columns (packed & micropacked)

... of hydrogen sulfide and methyl mercaptan. It is then treated to achieve effective separation of hydrocarbons...

Protect Natural Gas Sample Integrity and Prevent Sulfur Loss with Sulfinert Sample Cylinders (PDF 612kB)

.... Sulfur containing compounds, such as hydrogen sulfide, mercaptans, and thiophenes, are extremely reactive to the sample loop were Sulfinert-passivated to minimize sulfur adsorption. To determine losses, ethyl mercaptan...

Analyze Sulfur Compounds at ppb Levels Using an Rt-XLSulfur Micropacked Column or an Rtx-1 Thick Film Capillary Column (PDF 483kB)

... Peaks 1. Hydrogen sulfide 2. Sulfur dioxide 3. Carbonyl sulfide 4. Methyl mercaptan 5. Ethyl mercaptan 6. Carbon disulfide 7. Dimethyl sulfide 8. 2-Propyl mercaptan 9. Allyl mercaptan 10. 1-Propyl...

Rt-XLSulfur Packed GC Column for Analysis of Low-Level Sulfur Compounds in C1-C6 Hydrocarbon Streams (PDF 536kB)

..., especially hydrogen sulfide and methyl mercaptan, are easily adsorbed by undeactivated surfaces. Therefore is extensively deactivated for the analysis of low ppbv levels of hydrogen sulfide and methyl mercaptan...

GC Analysis of Total Reduced Sulfurs at ppbv Levels Using an Rxi-1ms Column and Sulfur Chemiluminescence Detection

..., dimethyl sulfide, hydrogen sulfide, and methyl mercaptan. While these methods do not specify sulfide, methyl mercaptan, ethyl mercaptan, and dimethyl sulfide in helium, using a Sulfinert ... sulfide, carbonyl sulfide, dimethyl sulfide, mercaptans) on our new column, with excellent peak shapes ... chemiluminescence, dimethyl sulfide, mercaptans, sulfur, inertness, hydrogen sulfide...

Gas Sampling Bags: Cost-Effective Alternatives for Air Sampling (PDF 2349kB)

... monoxide, sulfur dioxide, hydrogen sulfide, radon, and mercaptans. • Suitable for sampling most VOCs Compound Recommended Sampling Bag Material ALTEF Multi-Layer Foil n-Butyl mercaptan ✖ ✖ tert...

Rt-XLSulfur Packed Column: Specialized packed and micropacked columns for eXtra-Low Sulfur analysis (PDF 331kB)

... Rate: 9 mL/min. Detector SCD Peaks 1. Hydrogen sulfide 2. Carbonyl sulfide 3. Methyl mercaptan 4 . Ethyl mercaptan 5. Dimethyl sulfide 6. Dimethyl disulfide Commonly Asked Questions • What...

Sulfinert-Treated Sample Cylinders Store Active Sulfur Compounds at ppb Levels

... mercaptan, ethyl mercaptan, carbonyl sulfide, and dimethyl disulfide exhibited greater than 90% recovery ... -treated cylinder; recoveries of methyl mercaptan, ethyl mercaptan, carbonyl sulfide, and dimethyl disulfide...

Solvent Compatibility Chart for Filter Vials (PDF 304kB)

... solution) surfactant/detergent Methyl Ethyl Ketone (MEK) ketone Mercaptoethanol, 0.1M alcohol/mercaptan...

Thomson SINGLE StEP Filter Vials (PDF 738kB)

.../detergent Methyl Ethyl Ketone (MEK) ketone Mercaptoethanol, 0.1M alcohol/mercaptan Methyl Acetate ester...

Thermal Desorption: A Practical Applications Guide: I. Environmental Air Monitoring and Occupational Health & Safety (PDF 1087kB)

... Government Guidance Method - Standard Method for Off-Odour Analysis (2005) H2S CS2 Ethyl mercaptan Dimethyl sulphide Dimethyl disulphide Methyl mercaptan Typical TD-GC analytical conditions: Sample...

ChromaBLOGraphy: Maximum temperatures of packed columns – Sulfur Gases

For my fifth and final post in this series, I would like to focus on packed columns for light sulfur gases.  Compounds include (but not limited to) hydrogen sulfide, sulfur hexafluoride, carbonyl sulfide, sulfur dioxide, methyl mercaptan, ethyl mercaptan, etc. Because some analysts prefer PTFE tubing and/or PTFE frits for their columns, the maximum temperature […]

Protect Natural Gas Sample Integrity and Prevent Sulfur Loss with Sulfinert Sample Cylinders

.... Sulfur containing compounds, such as hydrogen sulfide, mercaptans, and thiophenes, are extremely reactive adsorption. To determine losses, ethyl mercaptan was monitored over time using dimethyl sulfide, a stable...

Rt-XLSulfur Packed GC Column for Analysis of Low-Level Sulfur Compounds in C1-C6 Hydrocarbon Streams

... compounds, especially hydrogen sulfide and methyl mercaptan, are easily adsorbed by undeactivated surfaces for the analysis of low ppbv levels of hydrogen sulfide and methyl mercaptan, and then is prepared to achieve...

Stable Sulfur & Mercury Sampling in Refineries Using Siltek and Sulfinert Surface Treated Components

...; methyl mercaptan, ethyl mercaptan, carbonyl sulfide, and dimethyl disulfide exhibited greater than 90...

Restek's PLOT Column Family (PDF 3255kB)

..., and mercaptans in hydrocarbon streams. • Stable to 190 °C. Formaldehyde on Rt-U-BOND Column Rt-U-BOND, 30 m, 0...

News: Analysis of Gases via Gas Chromatography: Part 2: Sulfur Gases

Author: Jaap de Zeeuw Restek Corporation Published By:  J. Sep. Sci. Year of Publication: 2016 Link: http://www.sepscience.com/Bespoke-Products-List?pgid=115&artid=4442 Abstract: Sulfur components are widely present in many raw materials used for hydrocarbon processing. The sulfur components are undesirable because they have a strong smell, … Continue reading

Rapid Characterization of Garlic Volatiles—No Sample Prep Required! Using Headspace GC/MS and an Rxi-5ms Capillary Column

...,3'-thiobis-1-propene, allyl mercaptan and diallyl disulfide. Diallyl disulfide appeared to be the dominant...

ChromaBLOGraphy: Sampling and analysis of landfill gas / biogas, an overview

Lately it seems that the sampling and analysis of landfill gas / biogas is a popular topic among our customers.  When initially ask about the topic, I had an idea of what customers were trying to do, but didn’t really have a firm grasp on the topic.  As I dug deeper, I began to realize just […]

Using Micropacked GC Columns for Analyzing Volatiles in Light Hydrocarbon Streams

... inertness is also very important as reactive sulfur compounds, such as hydrogen sulfide and methyl mercaptan...

ChromaBLOGraphy: Does Hydrogen as the Carrier gas, Negatively Impact the Peak Shape when using Siltek or Sulf-Inert Deactivated surfaces?

There is an increased interest in using hydrogen as the carrier gas. Not only because of its guaranteed availability, it also gives a significant benefit in analysis time. The only thing to be aware of, is to translate the operation conditions the right way, see: Use of hydrogen is often perceived as dangerous which is [...]

News: Restek Chromatographers Share Their Insights at COLACRO XIV

Beautiful Florianópolis in Santa Catarina, Brazil, was the site of this year’s Congresso Latino Americano de Cromatografia e Técnicas Relacionadas (COLACRO). Perhaps the most influential meeting on chromatography in South America, this biannual event was originally scheduled to be in … Continue reading

Restek's PLOT Column Family PCSS1163G-UNV

Restek's porous layer open tubular (PLOT) columns feature an innovative bonding process that minimizes particle release, more consistent flow for stable retention times, and outstanding peak symmetry to improve impurity analysis. Restek PLOT columns are the benchmark for performance.

News: Deactivation of Metal Surfaces: Applications in Gas Chromatography (GC) for the Past 15 Years

Author: Jaap de Zeeuw Restek Corporation Published By: American Laboratory Year of Publication: 2012 Link: www.americanlaboratory.com/913-Technical-Articles/124285-Deactivation-of-Metal-Surfaces-Applications-in-Gas-Chromatography-GC-for-the-Past-15-Years/ Abstract: In 1987, Restek Corporation introduced a new way to deactivate metal columns, called Silcosteel®. The original surface was shielded in such a way … Continue reading

For advanced chromatogram searching, please check out our Chromatogram Library Search Tool.

Sulfur Compounds and Hydrocarbons on Rt-XLSulfur

GC_PC00436

Column: Siltek, 1m, 0.95mm OD, 0.75 mm ID (cat.# 19806)
Injector: Not On-Column - Packed
Detector: SCD/FID

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us